- Home
- > Cable
- > Marine Cable
SXXI(i) screened fire resistance instrumentation cable
SXXI(i) screened fire resistance instrumentation cable
SXXI(i) screened fire resistance instrumentation cable application
This cable is designed for telephone & instrument circuits up to 150/250V.Suitable for use in commercial marine applications
SXXI(i) screened fire resistance instrumentation cable standards
Design guide : IEC 60092-350 & IEC 60092-376
Insulation material : IEC 60092-351, XLPE
Sheath material : IEC 60092-359, SHF1
Flame retardant : IEC 60332-1 & IEC 60332-3 Category A
Fire retardant : IEC 60331-21(90min)
IEC 60331-1,-2(120min)
Halogen content : IEC 60754-1, 0.5%
Smoke emission : IEC 61034, 60%
SXXI(i) screened fire resistance instrumentation cable construction
Classification | Code | Construction detail |
Conductor |
|
Stranded plain annealed copper wires as per IEC 60228, Class 2 |
Fire resisting layer | S | Mica/glass tape |
Insulation | XLPE as per IEC 60092-351 | |
Twisting |
|
Two/Three Insulated cores shall be twisted together to form a pair/triad |
Individual screen | (i) |
-Screened by AL/PS tape with tinned copper drain wire -Each pair/triad is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triads |
Cabling |
|
- Screened pairs/triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used - Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable |
Collective screen | (c) |
- Screened by AL/PS tape with tinned copper drain wire - A suitable tape may be applied on the collective screen - In case of 250V BI(i)cable, collective screen is omitted - SHF1 as per IEC 60092-359 |
Sheath | I |
- Sheath color : Black - Colored insulation plus Arabic number printing on the insulation |
Core identification |
|
Pair : White, Black Triad : White, Red, Black |
The other color of sheath and insulation may be applicable when purchaser required.
Stranded tinned annealed copper wire as per IEC 60228, Class 2 may be applicable when purchaser required.
SXXI(i) screened fire resistance instrumentation cable construction
SXXI(i) screened fire resistance instrumentation cable Specification
Cores: 1P, 2P,3P,4P,5P,7P,10P,12P,14P,16P,19P,20P, 24P, 30P (P:Pair)
1T, 2T,3T,4T,5T,7T,10T,12T,14T,16T,19T,20T, 24T, 30T (Triad)
Size (sqmm): 0.75, 1, 1.5, 2.5
SXXI(i) screened fire resistance instrumentation cable show
Cable Sample
Workshop