50 Persons Marine Sewage Treatment Separator
1. Purpose:
The sewage treatment separator is applicable to treat the sewage and the grey water from the toilet, to meet the standard of IMO. MEPC159(55), and discharge the effluent overboard.
2. Working Condition:
Environment Condition
Working Environment Temperature: 0℃~+50℃
Environment Relative Humidity: ≤90%
Voltage: AC380V/50Hz/3φ
3. Composition:
The separator consists of main components as follows:
No. |
Name |
Unit |
Qty. |
Remarks |
1 |
Main body(buffer tank、sequence tank) |
Set |
1 |
Q235-A |
2 |
Cutting pump(50CPW0.5-10B) |
Set |
1 |
|
3 |
Air pump(CYBW-20 ) |
Set |
1 |
|
4 |
Discharge pump (CLH40-32-2(Z)A) |
Set |
1 |
|
5 |
Dosing pump(DL7-5) |
Set |
1 |
|
6 |
Membrane assembly(6040W) |
Set |
1 |
|
7 |
UV-sterilizer(JX-0.5UV) |
Set |
1 |
|
8 |
Electric control box |
Set |
1 |
|
9 |
Motor two-way ball valve(C800-40BF) |
Pc |
1 |
|
10 |
Flowmeter(Z-6016) |
Pcs |
2 |
|
11 |
Level switch |
Pcs |
2 |
|
12 |
Pressure gauge(YC60 0~0.6MPa) |
Pcs |
3 |
|
4. Specifications:
Model: WCMBR-50(U)
Usage of person: Rated usage of person: 50P
Treatment capacity: Average: 3780L/d
Effluent quality:
BOD5≯25mg/L
TSS≯35mg/L
Coliform≯100MPN/100ml
COD≯125 mg/L
PH=6~8.5
Residual chlorine<0.5mg/l
Effluent pressure: 0.10MPa
Compressed air (provided by the client): 0.1~0.3MPa, 0.2m3/h.
Membrane flush water: Fresh water, Pressure: 0.1~0.3MPa.
5. Certificate