- Home
- > Cable
- > Marine Cable
JIS C 3410 individual screen control cable
JIS C 3410 individual screen control cable
JIS C 3410 individual screen control cable application
The cable is fixed installation, used for Control, signal system in ship.
JIS C 3410 individual screen control cable model
250V MPY-S, FA-MPY-S250V MPYC-S, FA-MPYC-S
250V MPYCY-S, FA-MPYCY-S
JIS C 3410 individual screen control cable standards
- Design guide : JIS C 3410(1999)- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature :85
JIS C 3410 individual screen control cable Construction
Classification |
Code |
Construction details |
Conductor |
M |
Tinned Copper Wire JIS C3410 |
Insulation |
P |
EPR as per JIS C 3410 |
Individual Shield |
-S |
Tinned Copper Wire |
Sheath |
Y |
PVC as per JIS C 3410 |
Armor |
C |
Galvanized steel wire braided |
CB |
Tinned copper wire braided |
|
Paint |
The white paint should be painted uniformly |
|
Covering |
Y |
PVC as per JIS C 3410 |
Color: Black |
JIS C 3410 individual screen control cable Parameter
250V (FA-) MPY-S
No. of cores |
Conductor |
Thick. of insulation |
Dia. of shield wire |
Thick. of bedding |
(FA-) MPY-S | ||||
Size | Construction | O.D |
Nom. overall dia |
Tolerance |
Cable Weight |
||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.1 |
9.9 |
0.4 |
150 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.2 |
11.6 |
0.5 |
230 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.3 |
13.9 |
0.6 |
350 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.4 |
18.2 |
0.8 |
570 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.5 |
21.5 |
0.9 |
840 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.7 |
26 |
1.1 |
1200 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.8 |
29.2 |
1.2 |
1600 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
2 |
33.2 |
1.4 |
2000 |
250V (FA-) MPYC-S
No. of cores |
Conductor |
Thick. of insulation |
Dia. of shield wire |
Thick. of bedding |
Dia. of steel wire |
(FA-) MPYC-S | ||||
Size | Construction | O.D |
Nom. overall dia |
Tolerance |
Cable Weight |
|||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.1 |
0.3 |
11.2 |
0.4 |
210 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.2 |
0.3 |
12.9 |
0.5 |
300 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.3 |
0.3 |
15.2 |
0.6 |
435 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.4 |
0.3 |
19.5 |
0.8 |
685 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.5 |
0.3 |
22.8 |
0.9 |
980 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.7 |
0.3 |
27.3 |
1.1 |
1360 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.8 |
0.3 |
30.5 |
1.2 |
1760 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
2 |
0.4 |
35 |
1.4 |
2240 |
250V (FA-) MPYCY-S
No. of cores |
Conductor |
Thick. of insulation |
Dia. of shield wire |
Thick. of bedding |
Dia. of steel wire |
Thick. of covering |
(FA-) MPYCY-S | ||||
Size | Construction | O.D |
Nom. overall dia |
Tolerance |
Cable Weight |
||||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.1 |
0.3 |
0.9 |
13.2 |
0.5 |
260 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.2 |
0.3 |
0.9 |
14.9 |
0.6 |
360 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.3 |
0.3 |
1 |
17.4 |
0.7 |
515 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.4 |
0.3 |
1.1 |
21.9 |
0.9 |
795 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.5 |
0.3 |
1.2 |
25.4 |
1 |
1120 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.7 |
0.3 |
1.3 |
30.1 |
1.2 |
1540 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
1.8 |
0.3 |
1.4 |
33.5 |
1.3 |
1970 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
0.12 |
2 |
0.4 |
1.5 |
38.4 |
1.5 |
2500 |
JIS C 3410 individual screen control cable show