JIS C3410 Collective screen control cable

JIS C3410 Collective screen control cable

JIS C3410 Collective screen control cable

JIS C3410 Collective screen control cable application

This cable is for fixed installation,used in control and signal system in ship.

JIS C3410 Collective screen control cable Applied Standard

-JISC 3410-1999
-IEC 60092-350
-IEC 60332-1
-IEC 60332-3 Cat.AF(for FA-type)

JIS C3410 Collective screen control cable service condition

Voltage rating: 250V
Maximum conductor temperature:85°C

JIS C3410 Collective screen control cable constrcution

MPYCYS Construction.jpg

Classification

Code

Construction details

Conductor

M

Tinned Copper Wire JIS C3410

Insulation

P

EPR as per JIS C 3410

Common Shield

S

Tinned Copper Wire

Sheath

Y

PVC as per JIS C 3410

Armor

C

Galvanized steel wire braided

CB

Tinned copper wire braided

Paint

The white paint should be painted uniformly

Covering

Y

PVC as per JIS C 3410

Color: Black

JIS C3410 Collective screen control cable parameter

250V (FA-) MPYS
No. of
cores
Conductor Thick. of
insulation
Dia. of
shield
wire
Thick. of
bedding
(FA-) MPYS
Size Construction O.D Nom.
overall dia
Tolerance Cable
Weight
mm² No./mm mm mm mm mm mm mm kg/km

2

1

7/0.43

1.29

0.7

0.14

1.1

9.4

0.4

135

4

1

7/0.43

1.29

0.7

0.14

1.1

10.6

0.5

190

7

1

7/0.43

1.29

0.7

0.14

1.2

12.6

0.6

270

12

1

7/0.43

1.29

0.7

0.16

1.3

16.3

0.7

430

19

1

7/0.43

1.29

0.7

0.16

1.5

19.3

0.8

600

27

1

7/0.43

1.29

0.7

0.18

1.6

23

1

840

37

1

7/0.43

1.29

0.7

0.18

1.7

25.7

1.1

1070

44

1

7/0.43

1.29

0.7

0.18

1.8

28.9

1.2

1290

250V (FA-) MPYCS

No. of
cores
Conductor Thick. of
insulation
Dia. of
shield
wire
Thick. of
bedding
Dia. of
steel wire
(FA-) MPYCS
Size Construction O.D Nom.
overall dia
Tolerance Cable
Weight
mm² No./mm mm mm mm mm mm mm mm kg/km

2

1

7/0.43

1.29

0.7

0.14

1.1

0.3

10.7

0.4

205

4

1

7/0.43

1.29

0.7

0.14

1.1

0.3

11.9

0.5

260

7

1

7/0.43

1.29

0.7

0.14

1.2

0.3

13.9

0.6

355

12

1

7/0.43

1.29

0.7

0.16

1.3

0.3

17.6

0.7

540

19

1

7/0.43

1.29

0.7

0.16

1.5

0.3

20.6

0.8

735

27

1

7/0.43

1.29

0.7

0.18

1.6

0.3

24.3

1

995

37

1

7/0.43

1.29

0.7

0.18

1.7

0.3

27

1.1

1240

44

1

7/0.43

1.29

0.7

0.18

1.8

0.3

30.2

1.2

1480

250V (FA-) MPYCYS

No. of
cores
Conductor Thick. of
insulation
Dia. of
shield
wire
Thick. of
bedding
Dia. of
steel wire
Thick. of
covering
(FA-) MPYCYS
Size Construction O.D Nom.
overall dia
Tolerance Cable
Weight
mm² No./mm mm mm mm mm mm mm mm mm kg/km

2

1

7/0.43

1.29

0.7

0.14

1.1

0.3

0.9

12.7

0.5

255

4

1

7/0.43

1.29

0.7

0.14

1.1

0.3

0.9

13.9

0.6

315

7

1

7/0.43

1.29

0.7

0.14

1.2

0.3

0.9

15.9

0.6

420

12

1

7/0.43

1.29

0.7

0.16

1.3

0.3

1

19.8

0.8

625

19

1

7/0.43

1.29

0.7

0.16

1.5

0.3

1.1

23

0.9

850

27

1

7/0.43

1.29

0.7

0.18

1.6

0.3

1.2

26.9

1.1

1140

37

1

7/0.43

1.29

0.7

0.18

1.7

0.3

1.3

29.8

1.2

1410

44

1

7/0.43

1.29

0.7

0.18

1.8

0.3

1.4

33.2

1.3

1680


JIS C3410 Collective screen control cable Show

testing equipment.jpg
Testing lab

produce equipment 3.jpg

Workshop

CONTACT WITH US NOW

Our mail: manager@hiseamarine.com

Society certificates

Hi-Sea Group-Obtained-certification