XLPE insulated marine instrumentation cable

XLPE insulated marine instrumentation cable

XLPE insulated marine instrumentation cable

XLPE insulated marine instrumentation cable application

This cable is used on ships,petrol platforms and offshore buildings for telecommunication,instrumentation and signal proceeding system.

XLPE insulated marine instrumentation cable Service Condition

Rated Voltage:150/250(300)V

Short ( the longest duration of no more than 5S) of the conductor temperature does not exceed 250℃

Laying temperature should not be less than 0 ℃, the minimum bending radius of single core cables should be 20D, multi-core cables 15D (D is the cable diameter ) .

XLPE insulated marine instrumentation cable Model

Model Product Name
CHJV/DA/SA/NA
XLPE insulated PVC sheathed shipboard communication cables , DA Type / SA Type / NA type
CHJV80/DA/SA/NA
XLPE insulated PVC inner sheathed copper wire braided armored marine communication cable , DA Type / SA Type / NA type
CHJV82/DA/SA/NA
XLPE insulated PVC inner sheathed copper wire braid armored PVC jacket Shipboard telecommunication cables , DA Type / SA Type / NA type
CHJV90/DA/SA/NA
XLPE insulated PVC inner sheathed steel wire braid armored marine communication cable , DA Type / SA Type / NA type
CHJV92/DA/SA/NA
XLPE insulated PVC inner sheath woven steel wire armored PVC jacket Shipboard telecommunication cables , DA Type / SA Type / NA
CHJVP82/DA/SA/NA
XLPE insulated wire pair shielded PVC inner sheathed copper wire braid armored PVC jacket Shipboard telecommunication cables , DA Type / SA Type / NA type
CHJVP92/DA/SA/NA
XLPE insulated PVC inner sheath pair shielded steel wire braid armored PVC jacket Shipboard telecommunication cables , DA Type / SA Type / NA type

XLPE insulated marine instrumentation cable Specifications

Size
CHJ86/SC CHJ85/SC CHJPF86/SC CHJPJ85/SC
Diameter(mm)
Reference Weight(kg/km)
Diameter(mm)
Reference Weight(kg/km)
Min. Max. Min. Max.
1x2x0.75 7.4 8.6 85 9.0 10.5 120
2x2x0.75* 8.2 9.6 109 10.5 13.5 162
2x2x0.75 10.0 12.0 135 12.0 14.0 190
4x2x0.75 11.5 13.5 195 13.0 15.5 250
7x2x0.75 14.0 16.5 315 16.0 18.5 390
10x2x0.75 18.0 20.5 435 19.5 22.0 525
12x2x0.75 18.5 21.0 480 20.5 23.0 590
14x2x0.75 19.5 22.0 540 21.5 24.0 645
16x2x0.75 20.5 23.0 590 22.5 25.0 705
19x2x0.75 21.5 24.0 665 23.5 26.5 790
24x2x0.75 25.0 28.0 835 27.0 30.5 985
1x3x0.75 7.6 9.0 95 9.2 11.0 135
4x3x0.75 13.0 15.0 245 14.5 17.0 310
7x3x0.75 15.5 18.0 405 17.5 20.0 495
10x3x0.75 20.0 22.5 565 22.0 24.5 675
1x2x1 7.8 9.2 90 9.4 11.0 130
2x2x1* 8.6 10.0 133 10.5 12.5 174
2x2x1 10.5 12.5 155 12.5 14.5 210
4x2x1 12.5 14.5 225 14.0 16.0 280
7x2x1 15.0 17.5 365 17.0 19.5 445
10x2x1 19.0 21.5 500 21.0 24.0 620
12x2x1 19.5 22.5 560 22.0 24.5 675
14x2x1 20.5 23.5 630 22.5 25.5 745
16x2x1 22.0 24.5 695 24.0 27.0 825
19x2x1 23.0 26.0 795 25.5 28.5 930
24x2x1 27.0 30.0 990 29.0 32.5 1145
1x3x1 8.2 9.6 110 9.6 11.5 145
4x3x1 13.5 16.0 285 15.5 17.5 355
7x3x1 17.0 19.0 475 19.0 21.5 570
10x3x1 21.5 24.0 665 23.5 26.5 780
1x2x1.5 9.0 10.5 120 10.0 12.0 155
2x2x1.5* 10.0 12.0 165 13.0 16.0 237
2x2x1.5 12.5 14.5 200 14.0 16.5 260
4x2x1.5 15.0 17.5 340 17.0 19.0 420
7x2x1.5 18.0 20.5 495 19.5 22.0 585
10x2x1.5 22.5 25.5 690 24.5 27.5 815
12x2x1.5 23.5 26.5 775 25.5 28.5 915
14x2x1.5 24.5 27.5 865 26.5 30.0 1015
16x2x1.5 26.0 29.0 965 28.0 31.5 1120
19x2x1.5 27.5 30.5 1095 29.5 33.0 1280
24x2x1.5 32.0 36.0 1380 34.5 38.5 1600
1x3x1.5 9.4 11.0 140 10.5 12.5 180
4x3x1.5 16.5 19.0 435 18.5 21.0 525
7x3x1.5 20.0 22.5 655 22.0 24.5 765
10x3x1.5 25.5 28.5 925 27.5 31.0 1.70
Note:2 pair of non-screened cable are assembled as a quad

XLPE insulated marine instrumentation cable Structure

150 250V marine instrumentation cable.jpg

XLPE insulated marine instrumentation cable Show

150 250V instrumetnation marine power cable.jpg

If you need more detailed information,please do not hesitate to contact me,I will try all my best to help you out.

CONTACT WITH US NOW

Our mail: manager@hiseamarine.com

Society certificates

Hi-Sea Group-Obtained-certification