SFOI(i) screened fire resistant instrumentation cable

SFOI(i) screened fire resistant instrumentation cable

SFOI(i) screened fire resistant instrumentation cable

SFOI(i) screened fire resistant instrumentation cable application

This cable is designed for telephone & instrument circuits up to 150/250V.

Suitable for use in commercial marine applications

Maximum conductor temperature : 90℃

SFOI(i) screened fire resistant instrumentation cable standards

Design Guide : IEC 60092-350, 376

Insulation Material : IEC 60092-351

Sheath Material : IEC 60092-359

Flammability : IEC 60332-1 &
IEC 60332-3 Category A

Fire Resistance : IEC 60331 (750℃or 1000℃)

Halogen Content : IEC 60754-1,2, 0.5%(Max.)Smoke Emission : IEC 61034-1,2, 60%(Min.)

SFOI screened fire resistant instrumentation cable model

150/250V SFOI(c)

150/250V SFOI(i)

150/250V SFOI(i&c)

SFOI screened fire resistant instrumentation cable construction

SFOI(i)-construction.jpg

Classification Code Construction detail
Conductor
Stranded plain annealed copper wires as per IEC 60228, Class 2
Fire resisting layer S Mica/glass tape
Insulation XLPE as per IEC 60092-351
Twisting
Two/Three Insulated cores shall be twisted together to form a pair/triad
Individual screen (i) - Screened by AL/PS tape with tinned copper drain wire
- Each pair/triad is wrapped with polyester tape to prevent electrical
contact with adjacent pairs/triads
Cabling
- Screened pairs/triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used
- Suitable tape(s) may be applied on the cabled core
- A Filler may be applied to obtain a circular Cable
Collective screen (c) - Screened by AL/PS tape with tinned copper drain wire
- A suitable tape may be applied on the collective screen
- In case of 250V BI(i)cable, collective screen is omitted
- SHF1 as per IEC 60092-359
Inner Covering F Non-hygroscopic material
Armor O - Braid of plain annealed copper wire
- Coverage density : Min. 90%
Sheath I - Sheath color : Black
- Colored insulation plus Arabic number printing on the insulation
Core identification
Pair : White, Black Triad : White, Red, Black
Note.
The other color of sheath and insulation may be applicable when purchaser required.
Stranded tinned annealed copper wire as per IEC 60228, Class 2 may be applicable when purchaser required.

SFOI screened fire resistant instrumentation cable specification

Cores: 1P, 2P,3P,4P,5P,7P,10P,12P,14P,16P,19P,20P, 24P, 30P (P:Pair)

1T, 2T,3T,4T,5T,7T,10T,12T,14T,16T,19T,20T, 24T, 30T (Triad)

Size (sqmm): 0.75, 1, 1.5, 2.5

SFOI screened fire resistant instrumentation cable show

marine-communication-cable.jpg

Cable Sample

produce equipment 3.jpg

Workshop

testing equipment.jpg

Testing Lab

CONTACT WITH US NOW

Our mail: manager@hiseamarine.com

Society certificates

Hi-Sea Group-Obtained-certification