SFOI(i) screened fire resistant instrumentation cable
SFOI(i) screened fire resistant instrumentation cable
SFOI(i) screened fire resistant instrumentation cable application
This cable is designed for telephone & instrument circuits up to 150/250V.
Suitable for use in commercial marine applications
Maximum conductor temperature : 90℃
SFOI(i) screened fire resistant instrumentation cable standards
Design Guide : IEC 60092-350, 376
Insulation Material : IEC 60092-351
Sheath Material : IEC 60092-359
Flammability : IEC 60332-1 &
IEC 60332-3 Category A
Fire Resistance : IEC 60331 (750℃or 1000℃)
Halogen Content : IEC 60754-1,2, 0.5%(Max.)Smoke Emission : IEC 61034-1,2, 60%(Min.)
SFOI screened fire resistant instrumentation cable model
150/250V SFOI(c)
150/250V SFOI(i)
150/250V SFOI(i&c)
SFOI screened fire resistant instrumentation cable construction
Classification | Code | Construction detail |
Conductor |
|
Stranded plain annealed copper wires as per IEC 60228, Class 2 |
Fire resisting layer | S | Mica/glass tape |
Insulation | XLPE as per IEC 60092-351 | |
Twisting |
|
Two/Three Insulated cores shall be twisted together to form a pair/triad |
Individual screen | (i) |
- Screened by AL/PS tape with tinned copper drain wire - Each pair/triad is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triads |
Cabling |
|
- Screened pairs/triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used - Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable |
Collective screen | (c) |
- Screened by AL/PS tape with tinned copper drain wire - A suitable tape may be applied on the collective screen - In case of 250V BI(i)cable, collective screen is omitted - SHF1 as per IEC 60092-359 |
Inner Covering | F | Non-hygroscopic material |
Armor | O |
- Braid of plain annealed copper wire - Coverage density : Min. 90% |
Sheath | I |
- Sheath color : Black - Colored insulation plus Arabic number printing on the insulation |
Core identification |
|
Pair : White, Black Triad : White, Red, Black |
The other color of sheath and insulation may be applicable when purchaser required.
Stranded tinned annealed copper wire as per IEC 60228, Class 2 may be applicable when purchaser required.
SFOI screened fire resistant instrumentation cable specification
Cores: 1P, 2P,3P,4P,5P,7P,10P,12P,14P,16P,19P,20P, 24P, 30P (P:Pair)
1T, 2T,3T,4T,5T,7T,10T,12T,14T,16T,19T,20T, 24T, 30T (Triad)
Size (sqmm): 0.75, 1, 1.5, 2.5
SFOI screened fire resistant instrumentation cable show
Cable Sample
Workshop
Testing Lab