1.rated voltage U0 / U 3.6/6kV, used to power all ground mobile Mining Equipment that rated voltage is 3.6/6kv
2.maximum allowable conductor temperature: 65℃ 90 ℃
3.Permissible minimum working temperature is -35 ℃
4.cable bend radius less than six times the cable diameter.
If you feel this is not what you are looking for,please kindly check more Mobile cable here,also you can check more cable here,or you can use the search form on the upper right corner.
Mobile Shielded Rubber Sheathed Cable Model
Model | Product Name | Application |
MYPT-1.9/3.3 | Mine Mobile Metal Shield Rubber sheath Flexible Cable | Power Connection for underground mobile mining equipment rated voltage 1.9/3.3kv |
MYP-3.6/6 |
Mine Mobile Shield Rubber sheath Flexible Cable |
Power Connection for ground mobile mining equipment rated voltage 3.6/6kv |
MYPT-3.6/6 |
Mine Mobile Metal Shield Rubber sheath Flexible Cable |
|
MYPT-6/10 |
Mine Mobile Metal Shield Rubber sheath Flexible Cable |
Power Connection for ground mobile mining equipment rated voltage 6/10kv |
3.6/6KV Coal mine Shielding Movable flexible cable Specifications:
Core Number*Conductor Nominal Section(mm2) | Nominal Thickness | Cable Outer Diameter | ||
Power Core | Earth Core | Power core Insulator | Outer Sheath | 3.6/6kv |
3*16 | 1*16 | 4.0 | 5.5 | 48.0~55.0 |
3*25 | 1*16 | 4.0 | 5.5 | 51.0~58.0 |
3*35 | 1*16 | 4.0 | 5.5 | 54.0~61.5 |
3*50 | 1*25 | 4.0 | 5.5 | 58.0~66.0 |
3*70 | 1*25 | 4.0 | 6.5 | 64.0~72.0 |
3*95 | 1*35 | 4.0 | 6.5 | 68.5~77.0 |
3*120 | 1*35 | 4.0 | 6.5 | 71.5~80.0 |
3*150 | 1*50 | 4.0 | 6.5 | 76.0~85.0 |
Note:Earth Core Section is the minimum. |
20° C Insulator Resistance Minimum (MΩ.km)
Conductor Nominal Section | 20° C Power Core Insulator Resistance Minimum (MΩ.km) |
16 | 750 |
25 | 650 |
35 | 550 |
50 | 500 |
70 | 450 |
95 | 400 |
120 | 350 |
150 | 350 |
3.6/6KV Coal mine Shielding Movable flexible cable Structure: