Mobile shielded flexible cable

Mobile shielded flexible cable

Mobile shielded flexible cable

1.rated voltage U0 / U 0.66/1.14kV, used to power all underground mobile Equipment that rated voltage is 0.66/1.14kv
2.maximum allowable conductor temperature: 65 ℃ 90 ℃
3.Permissible minimum working temperature is -35 ℃
4.cable bend radius less than six times the cable diameter.

If you feel this is not what you are looking for,please kindly check more Mobile cable here,also you can check more cable here,or you can use the search form on the upper right corner.

Mobile shielded flexible cable Model

Model Product Name Application
MY-0.38/0.66 Mine Mobile Rubber Sheath Flexible Cable Power Connection for Variety of underground mining equipment rated voltage 0.38/0.66kv
MYP-0.38/0.66 Mine Mobile Shield Rubber Sheath Flexible Cable
MYP-0.66/1.14 Mine Mobile Shield Rubber Sheath Flexible Cable
Power Connection for Variety of underground mining equipment rated voltage 0.66/1.14kv

0.66/1.14KV Coal mine Movable Shielding flexible cable specifications:

Single Core Cable Specifications:

Core Number*Conductor Nominal Section(mm2) Nominal Thickness(mm) Cable Outer Diameter(mm)
Power Core Insulator Sheath 0.38/0.66kv
1*4 1.4 1.5 8.0~10.0
1*6 1.4 1.6 9.0~12.0
1*10 1.6 1.8 11.0~14.0
1*16 1.6 1.9 12.0~15.0
1*25 1.8 2.0 14.0~17.5
1*35 1.8 2.2 16.0~19.5
1*50 2.0 2.4 18.5~22.5
1*70 2.0 2.6 21.0~25.0
1*95 2.2 2.8 23.5~28.5
1*120 2.2 3.0 25.5~29.5
1*150 2.4 3.2 28.0~33.0
1*185 2.4 3.4 30.5~35.5
1*240 2.6 3.5 34.0~39.5
1*300 2.6 3.6 37.0~43.0
1*400 2.8 3.8 42.0~48.0

0.66/1.14KV Movable Shielding Flexible Cable Specifications:

Core Number*Conductor Nominal Section(mm2) Nominal Thickness Cable Outer Diameter
Power Core Earth Core Power core Insulator Sheath 0.66/1.14kv
3*10 1*10 1.8 4.5 30.0~35.0
3*16 1*10 1.8 4.5 32.5~37.5
3*25 1*16 2.0 5.0 37.5~43.0
3*35 1*16 2.0 5.0 40.5~46.5
3*50 1*16 2.2 5.5 46.5~53.0
3*70 1*25 2.2 5.5 51.0~58.0
3*95 1*25 2.4 6.0 57.5~65.0
3*120 1*35 2.4 6.0 61.0~69.0
3*150 1*50 2.6 6.0 66.5~75.0
Note:Earth Core Section is the minimum.

20° C Insulator Resistance Minimum (MΩ.km)

Power Core Nominal Section 20° C Insulator Resistance Minimum (MΩ.km)
4 600
6 450
10 400
16 350
25 300
35 250
50 250
70 200
95 200
120 200
150 180
185 180
240 160
300 140
400 140

0.66/1.14KV Coal mine Movable Shielding flexible cable structure:

movable-flexible-cable-structure.jpg

0.66/1.14KV Coal mine Movable Shielding flexible cable Show:

cable workshop.jpg

Workshop

CONTACT WITH US NOW

Our mail: manager@hiseamarine.com

Society certificates

Hi-Sea Group-Obtained-certification