JQ.YJ601Ni2-1  Gas-shielded Flux-cored Welding Wire

JQ.YJ601Ni2-1 Gas-shielded Flux-cored Welding Wire

JQ.YJ601Ni2-1
GB:E551T1-Ni2
AWS:E81T1-Ni2
Current:Used for welding structures made of 590MPa low-alloy high strength steel. Widely used for welding some key structures like hoisting machinery, bridges, storage tanks, steel-frame structures, etc.
Main Applications:

JQ.YJ601Ni2-1

According with GB/T 17493-1998 E551T1-Ni2
Corresponding with AWS A5.29 E81T1-Ni2


Introduction: JQ.YJ601Ni2-1 is a kind of titania type CO2 gas-shielded flux-cored welding wire. It has excellent welding performance, soft and stable arc, fewer spatters, good slag detachability and beautiful appearance of weld. All-position welding. It has high welding efficiency. The weld metal has been given toughening treatment by microelements, so it has excellent low temperature toughness above -30℃ and good crack-resistance.


Uses: Used for welding structures made of 590MPa low-alloy high strength steel. Widely used for welding some key structures like hoisting machinery, bridges, storage tanks, steel-frame structures, etc.


Chemical Composition of Deposited Metal (%)
(CO2Shielding Gas)
Chemical Composition
C
Mn
Si
S
P
Ni
Guarantee Value
≤0.12
≤1.50
≤0.80
≤0.030
≤0.030
1.75-2.75
General Result
0.06
1.24
0.40
0.017
0.009
2.00

Mechanical Properties of Deposited Metal
Test Item
Rm(MPa)
ReL或Rp0.2(Mpa)
A(%)
KV2(J)
Guarantee Value
≥550
≥470
≥19
≥27(-40℃)
General Result
625
550
25
90

Reference Current (DC+)
Wire Diameter(mm) φ1.2 φ1.4 φ1.6
Current Range(A) Downhand Welding 120~300 150~400 180~450
Vertical Upward Welding and Overhead Position Welding 120~260 150~270 180~280
Vertical Downward Welding and Overhead Position Welding 200~300 220~300 250~300
Horizontal Welding 120~280 150~320 180~350

Instructions:
1.The oil stains and rust on the weldments should be cleared away.
2.When welding, the gas flow rate is generally 20~25L/min.
3.When welding with flux-cored welding wires, the extension elongation should be 15~25mm.
4.The humidity of the welding wire storerooms should be preserved below 60%.
5.It is not suitable for non-vacuum-packed welding wires to be stored for more than half a year, and it is not suitable for vacuum-packed welding wires to be stored for more than a year.