J506WCu Corrosion-resistant Steel Electrode
J506WCu
GB:E5016-G
AWS:
Current:Suitable for welding carbon steel and 490MPa tensile strength atmospheric corrosion-resistant steel structures, such as 09MnCuPTi. Also used for welding other low-alloy steel structures, such as 16Mn, etc.
AWS:
Current:Suitable for welding carbon steel and 490MPa tensile strength atmospheric corrosion-resistant steel structures, such as 09MnCuPTi. Also used for welding other low-alloy steel structures, such as 16Mn, etc.
J506WCu |
According with GB E5016-G |
||||||||||||||||
|
|||||||||||||||||
|
|||||||||||||||||
Chemical Composition of Deposited Metal (%)
|
|||||||||||||||||
Mechanical Properties of Deposited Metal
|
|||||||||||||||||
Diffusible Hydrogen Content in Deposited Metal: ≤6.0ml/100g(Glycerine Hydrogen Test) |
|||||||||||||||||
X-ray Radiographic Inspection: ⅠDegree |
|||||||||||||||||
Reference Current (AC, DC+)
|
|||||||||||||||||
Instructions: 1.The electrodes must be baked under about 350℃ for an hour before welding, and used as soon as baking is completed. 2.The stains on the weldments, such as rust, oil stains, moisture, etc., must be cleared away before welding. 3.When welding, short arc must be used and stringer bead is suitable. |
|
CONTACT WITH US NOW