JIS Shipboard Telephone cable

JIS Shipboard Telephone cable

JIS Shipboard Telephone cable

JIS Shipboard Telephone cable application

This cable is intended for telephone and instrumentation usage and fixed installation.

JIS Shipboard Telephone cable standards

- Design guide : JIS C 3410(1999)
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 60

JIS Shipboard Telephone cable Model

250V TTY, FA-TTY
250V TTYC, FA-TTYC
250V TTYCY, FA-TTYCY

JIS Shipboard Telephone cable construction

TTY Construction.jpg

Classification

Code

Construction details

Conductor

TT

Tinned Copper Wire JIS C3410

Insulation

Y

PVC as per JIS C 3410

Armor

C

Galvanized steel wire braided

CB

Tinned copper wire braided

Paint

The white paint should be painted uniformly

Covering

Y

PVC as per JIS C 3410

Color: Black

JIS Shipboard Telephone cable parameter

(FA-) TTY,TTPY
No. of
pair, Triad or
Quad
Conductor Thick. of
insulation
Thick. of
bedding
(FA-) TTY,TTPY
Size Construction O.D Nom.
overall dia
Tolerance Cable
Weight
mm² No./mm mm mm mm mm mm kg/km

1

0.75

7/0.37

1.1

0.7

1

7.9

0.4

70

1T

0.75

7/0.37

1.1

0.7

1.1

8.6

0.4

85

1Q

0.75

7/0.37

1.1

0.7

1.1

9.3

0.4

105

2

0.75

7/0.37

1.1

0.7

1.2

12

0.6

105

4

0.75

7/0.37

1.1

0.7

1.3

14.2

0.6

205

7

0.75

7/0.37

1.1

0.7

1.4

16.9

0.7

310

10

0.75

7/0.37

1.1

0.7

1.5

21.7

0.9

465

14

0.75

7/0.37

1.1

0.7

1.6

23.5

1

585

19

0.75

7/0.37

1.1

0.7

1.7

26.4

1.1

755

24

0.75

7/0.37

1.1

0.7

1.9

31.9

1.3

1030

30

0.75

7/0.37

1.1

0.7

2

34

1.4

1220

37

0.75

7/0.37

1.1

0.7

2.1

36.9

1.5

1450

48

0.75

7/0.37

1.1

0.7

2.3

42.8

1.7

1910

(FA-) TTYC,TTPYC

No. of
pair, Triad or
Quad
Conductor Thick. of
insulation
Thick. of
bedding
Dia. of
steel wire
(FA-) TTYC,TTPYC
Size Construction O.D Nom.
overall dia
Tolerance Cable
Weight
mm² No./mm mm mm mm mm mm mm kg/km

1

0.75

7/0.37

1.1

0.7

1

0.3

9.2

0.4

130

1T

0.75

7/0.37

1.1

0.7

1.1

0.3

9.9

0.4

155

1Q

0.75

7/0.37

1.1

0.7

1.1

0.3

10.6

0.4

180

2

0.75

7/0.37

1.1

0.7

1.2

0.3

13.6

0.6

180

4

0.75

7/0.37

1.1

0.7

1.3

0.3

15.5

0.6

320

7

0.75

7/0.37

1.1

0.7

1.4

0.3

18.2

0.7

440

10

0.75

7/0.37

1.1

0.7

1.5

0.3

23

0.9

640

14

0.75

7/0.37

1.1

0.7

1.6

0.3

24.8

1

770

19

0.75

7/0.37

1.1

0.7

1.7

0.3

27.7

1.1

965

24

0.75

7/0.37

1.1

0.7

1.9

0.4

33.7

1.3

1380

30

0.75

7/0.37

1.1

0.7

2

0.4

35.8

1.4

1590

37

0.75

7/0.37

1.1

0.7

2.1

0.4

38.7

1.5

1860

48

0.75

7/0.37

1.1

0.7

2.3

0.4

44.6

1.7

2380

(FA-) TTYCY,TTPYCY

No. of
pair, Triad or
Quad
Conductor Thick. of
insulation
Thick. of
bedding
Dia. of
steel wire
Thick. of
covering
(FA-) TTYCY,TTPYCY
Size Construction O.D Nom.
overall dia
Tolerance Cable
Weight
mm² No./mm mm mm mm mm mm mm mm kg/km

1

0.75

7/0.37

1.1

0.7

1

0.3

0.8

11

0.4

170

1T

0.75

7/0.37

1.1

0.7

1.1

0.3

0.9

11.7

0.5

205

1Q

0.75

7/0.37

1.1

0.7

1.1

0.3

0.9

12.6

0.5

230

2

0.75

7/0.37

1.1

0.7

1.2

0.3

0.9

15.5

0.7

230

4

0.75

7/0.37

1.1

0.7

1.3

0.3

1

17.7

0.7

400

7

0.75

7/0.37

1.1

0.7

1.4

0.3

1.1

20.6

0.8

545

10

0.75

7/0.37

1.1

0.7

1.5

0.3

1.2

25.6

1

775

14

0.75

7/0.37

1.1

0.7

1.6

0.3

1.2

27.4

1.1

920

19

0.75

7/0.37

1.1

0.7

1.7

0.3

1.3

30.5

1.2

1140

24

0.75

7/0.37

1.1

0.7

1.9

0.4

1.4

36.7

1.5

1610

30

0.75

7/0.37

1.1

0.7

2

0.4

1.5

39.2

1.6

1860

37

0.75

7/0.37

1.1

0.7

2.1

0.4

1.6

42.3

1.6

2170

48

0.75

7/0.37

1.1

0.7

2.3

0.4

1.7

48.4

1.8

2760

JIS Shipboard Telephone cable show

Cabling.jpg

Equipment

Finished Cable.jpg

Finished Cable

Test Lab1.jpg

Testing Lab

CONTACT WITH US NOW

Our mail: manager@hiseamarine.com

Society certificates

Hi-Sea Group-Obtained-certification