SIOI/SICI fire resistance power and control cable

SIOI/SICI fire resistance power and control cable

SIOI/SICI fire resistance power and control cable

SIOI/SICI fire resistance power and control cable application

This cable is designed for power, lighting & control circuits up to 0.6/1kV.Suitable for use in commercial marine applications

SIOI/SICI fire resistance power and control cable standards

- Design guide : IEC 60092-350 & IEC 60092-353
- Insulation material : IEC 60092-351, XLPE
- Sheath material : IEC 60092-359, SHF1
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A
- Fire resistance : IEC 60331-21(90min) IEC 60331-1,-2(120min)
- Halogen content : IEC 60754-1, 0.5%
- Smoke emission : IEC 61034, 60%
- Cold bend/impact : CSA 22.2 No. 0.3 (-40° / -35°
- Max. rated conductor temperature : 90°

SIOI/SICI fire resistance power and control cable construction

Classification Code Construction detail
Conductor
Stranded plain annealed copper wire as per IEC 60228, Class 2
Insulation S Mica/Glass tape
Insulation XLPE as per IEC 60092-351
Cabling
- Insulated conductors shall be cabled

- Flame retardant & non-hygroscopic fillers may be used

- Suitable tape(s) may be applied on the cabled core

- A Filler may be applied to obtain a circular Cable
Inner sheath I SHF1 as per IEC 60092-359
Armor O(C)

- Braid of plain annealed copper wire(o) or galvanized steel wire(c)

- Coverage density : Min. 90%

Outer sheath I SHF1 as per IEC 60092-359,Outer sheath color : Black

Note:
The other color of sheath and insulation may be applicable when purchaser required.
Stranded tinned annealed copper wire as per IEC 60228, Class 2 may be applicable when purchaser required.

SIOI/SICI fire resistance power and control cable show

Extruding.jpg

Extruding

Cabling.jpg

Production Machine

Finished Cable.jpg

Finished Cable

CONTACT WITH US NOW

Our mail: manager@hiseamarine.com

Society certificates

Hi-Sea Group-Obtained-certification