- Home
- > Cable
- > Marine Cable
JIS C 3410 Overall shield telephone cable
JIS C 3410 Overall shield telephone cable
JIS C 3410 Overall shield telephone cable application
Instrument circuit upto 250V, instrument safe systems.
Fixed installation for instrument, communication, control and alarm system in both explosion risk and safe areas, general purposes.
JIS C 3410 Overall shield telephone cable model
250V TTYS, FA- TTYS
250V TTYCS, FA- TTYCS
250V TTYCYS, FA- TTYCYS
JIS C 3410 Overall shield telephone cable standards
- Design guide : JIS C 3410(1999)
- Flame retardant :IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 60
JIS C 3410 Overall shield telephone cable construction
Classification |
Code |
Construction details |
Conductor |
TT |
Tinned Copper Wire JIS C3410 |
Insulation |
Y |
PVC as per JIS C 3410 |
Common Shield |
S |
Tinned Copper Wire |
Armor |
C |
Galvanized steel wire braided |
CB |
Tinned copper wire braided |
|
Paint |
The white paint should be painted uniformly |
|
Covering |
Y |
PVC as per JIS C 3410 |
Color: Black |
JIS C 3410 Overall shield telephone cable parameter
(FA-) TTYS,TTPYS
No. of pair, Triad or Quad |
Conductor |
Thick. of insulation |
Dia. of shield wire |
Thick. of bedding |
(FA-) TTYS,TTPYS | ||||
Size | Construction | O.D |
Nom. overall dia |
Tolerance |
Cable Weight |
||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | kg/km | |
1 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.14 |
1.1 |
8.8 |
0.4 |
120 |
1T |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.14 |
1.1 |
9.3 |
0.4 |
140 |
1Q |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.14 |
1.1 |
10 |
0.5 |
160 |
2 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.16 |
1.2 |
13 |
0.6 |
200 |
4 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.16 |
1.3 |
15 |
0.7 |
300 |
7 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.16 |
1.4 |
17.7 |
0.8 |
420 |
10 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.18 |
1.6 |
22.8 |
1.0 |
640 |
14 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.18 |
1.6 |
24.4 |
1.0 |
770 |
19 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.18 |
1.8 |
27.5 |
1.2 |
970 |
24 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.2 |
2 |
33.1 |
1.4 |
1290 |
30 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.26 |
2.1 |
35.5 |
1.5 |
1620 |
37 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.26 |
2.2 |
38.4 |
1.6 |
1890 |
48 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.26 |
2.4 |
44.3 |
1.7 |
2420 |
(FA-) TTYCS,TTPYCS
No. of pair, Triad or Quad |
Conductor |
Thick. of insulation |
Dia. of shield wire |
Thick. of bedding |
Dia. of steel wire |
(FA-) TTYCS,TTPYCS | ||||
Size | Construction | O.D |
Nom. overall dia |
Tolerance |
Cable Weight |
|||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
1 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.14 |
1.1 |
0.3 |
10.1 |
0.4 |
180 |
1T |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.14 |
1.1 |
0.3 |
10.6 |
0.4 |
205 |
1Q |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.14 |
1.1 |
0.3 |
11.3 |
0.5 |
230 |
2 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.16 |
1.2 |
0.3 |
14.6 |
0.7 |
230 |
4 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.16 |
1.3 |
0.3 |
16.3 |
0.7 |
405 |
7 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.16 |
1.4 |
0.3 |
19 |
0.7 |
545 |
10 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.18 |
1.6 |
0.3 |
24.1 |
1 |
800 |
14 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.18 |
1.6 |
0.3 |
25.7 |
1 |
935 |
19 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.18 |
1.8 |
0.3 |
28.8 |
1.2 |
1160 |
24 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.2 |
2 |
0.4 |
34.9 |
1.4 |
1600 |
30 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.26 |
2.1 |
0.4 |
37.3 |
1.5 |
1950 |
37 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.26 |
2.2 |
0.4 |
40.2 |
1.6 |
2250 |
48 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.26 |
2.4 |
0.4 |
46.1 |
1.7 |
2830 |
(FA-) TTYCYS,TTPYCYS
No. of pair, Triad or Quad |
Conductor |
Thick. of insulation |
Dia. of shield wire |
Thick. of bedding |
Dia. of steel wire |
Thick. of covering |
(FA-) TTYCYS,TTPYCYS | ||||
Size | Construction | O.D |
Nom. overall dia |
Tolerance |
Cable Weight |
||||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
1 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.14 |
1.1 |
0.3 |
0.9 |
12.1 |
0.5 |
230 |
1T |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.14 |
1.1 |
0.3 |
0.9 |
12.6 |
0.5 |
255 |
1Q |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.14 |
1.1 |
0.3 |
0.9 |
13.3 |
0.5 |
285 |
2 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.16 |
1.2 |
0.3 |
1 |
16.7 |
0.7 |
285 |
4 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.16 |
1.3 |
0.3 |
1 |
18.5 |
0.7 |
490 |
7 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.16 |
1.4 |
0.3 |
1.1 |
21.4 |
0.9 |
650 |
10 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.18 |
1.6 |
0.3 |
1.2 |
26.7 |
1.1 |
945 |
14 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.18 |
1.6 |
0.3 |
1.2 |
28.3 |
1.1 |
1090 |
19 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.18 |
1.8 |
0.3 |
1.3 |
31.6 |
1.3 |
1340 |
24 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.2 |
2 |
0.4 |
1.5 |
38.3 |
1.5 |
1860 |
30 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.26 |
2.1 |
0.4 |
1.5 |
40.7 |
1.6 |
2230 |
37 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.26 |
2.2 |
0.4 |
1.6 |
43.8 |
1.7 |
2570 |
48 |
0.75 |
7/0.37 |
1.1 |
0.7 |
0.26 |
2.4 |
0.4 |
1.8 |
50.1 |
1.8 |
3240 |
JIS C 3410 Overall shield telephone cable show
Testing
Workshop
CONTACT WITH US NOW