TIOI TICI screened flame retardant telephone cable

TIOI TICI screened flame retardant telephone cable

TIOI TICI screened flame retardant telephone cable

TIOI TICI screened flame retardant telephone cable application

This cable is designed for telephone & instrument circuits up to 150/250V.Suitable for use in commercial marine applications

For fixed installation in most areas and on open deck in ships.If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.

TIOI TICI screened flame retardant telephone cable standards

Design Guide : IEC 60092-350, 376
nsulation Material : IEC 60092-351
Sheath Material : IEC 60092-359
Flammability : IEC 60332-1 &
IEC 60332-3 Category A
Halogen Content : IEC 60754-1,2, 0.5%(Max.)
Smoke Emission : IEC 61034-1,2, 60%(Min.)

TIOI TICI screened flame retardant telephone cable construction

Classification Code Letter Construction Detail
Conductor
Plain (or Tinned), Annealed, Stranded copper wire
Insulation T Cross-linked Polyethylene (XLPE) as per IEC 60092-351
Individual Screen (i) Each pair/triad are individually screened by aluminium backed polyester tape
(AL/PS tape) with tinned copper drain wire.
Suitable binder tape may be wrapped on/below the individual screen.
Collective Screen (c) Pair/triad laid up and collective screened by aluminium backed polyester
tape (AL/PS tape) with tinned copper drain wire.
Suitable binder tape may be wrapped on/below the collective screen.
Inner Sheath I Halogen Free Thermoplastic compound (SHF1) as per IEC 60092-359
Armor C or O Galvanized Steel Wire Braid (C)
Copper Wire Braid (O)
Outer Sheath I Halogen Free Thermoplastic compound (IEC 60092-359, SHF1)
Sheath color
- Non-intrinsically safe cable : Black
- Intrinsically safe cable : Blue
TIOI-TICI-screened-telephone-cable-construction.jpg

TIOI TICI screened flame retardant telephone cable Electrical data

Loop resistance of pair, max. / +20°C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20°C
Minimum recommended installation temperature -15 °C

Lowest operation temperature -40 °C

TIOI TICI screened flame retardant telephone cable specification

Cores: 1P, 2P,3P,4P,5P,7P,10P,12P,14P,16P,19P,20P, 24P, 30P (P:Pair)
1T, 2T,3T,4T,5T,7T,10T,12T,14T,16T,19T,20T, 24T, 30T (Triad)
Size (sqmm): 0.75, 1, 1.5, 2.5