Thermocouples Extension Cable

Thermocouples Extension Cable

Thermocouples Extension Cable

1.Thermocouples Extension Cable Manufacturing standard

GB/T4989-94(Equal to IEC584-3)

2.Thermocouples Extension Cable Characteristics and use

General-purpose PVC insulated and sheathed, extension wires or cables have good moisture proof wear and flame proof properties.For continuous extruding technology being employed, heat-resistant, fluoroplatics insulated and sheathed extension wires or cables have improved advantages, eg.enduring high temperature extreme cold, acid/alkaline oil or water and aging the products can meet the requirements of GB/T4989-94(equal to IEC584-3).
  The extension wires used in the intrinsically safe, explosion-proof temperature-measuring system employ low-capacity、low-inductance materical, which is explosion-proof. They are used under the dangerous condition to form an intrinsically safe thermocouple temperature measuring system.

3.Thermocouples Extension Cable Service Condition

3.1 Max working temperature:Heat-resistant class: 200℃(F46); 260℃(PFA), 180℃ (Silicon rubber);General-purpose class: 70℃/105℃(PVC), 90℃(XLPE), 70℃(Low-smoke, halogen-free PO), 90℃/125℃(Low-smoke, halogen-free, cross-linked PO)
3.2 Min environment temperature:PVC sheath: -40℃(fixed laying), -15℃(non-fixed laying)Fluoroplastic or silicon rubber sheath: -60℃(fixed laying), -20℃(non-fixed laying)
3.3 Allowed bending radius: ≥6 times the outer diameter of the unarmored cable;≥12 times the outer diameter of the copper tape shielded or steel tape armored cable;≥10 times the outer diameter of the fluoroplastic insulated and sheathed cable.

If you feel this is not what you are looking for,please kindly check more special cable here,also you can check more cable here,or you can use the search form on the upper right corner.

4.Thermocouples Extension Cable Model

4.1Extension Wires Used in thermocouple(precision class,gradiation No.K)

Model Name
KX-GA-VV PVC insulated and sheathed thermocouple extension wire
KX-VA-VVR PVC insulated and sheathed thermocouple soft extension wire
KX-GA-VVP PVC insulated and sheathed thermocouple copper wire woven shield extension wire
KX-GA-VVRP PVC insulated and sheathed thermocouple copper wire woven shield soft extension wire
KX-HA-FF Fluoroplastic insulated and sheathed thermocouple extension wire
KX-HA-FFR Fluoroplastic insulated and sheathed thermocouple soft extension wire
KX-HA-FFP Fluoroplastic insulated and sheathed thermocouplecopper wire woven shield extension wire
KX-HA-FFRP Fluoroplastic insulated and sheathed thermocouple copper wire woven shield soft extension wire
KX-HA-FG Fluoroplastic insulated Silicon Rubber sheathed thermocouple extension wire
KX-HA-FGR Fluoroplastic insulated Silicon Rubber sheathed thermocouple soft extension wire
KX-HA-FGP Fluoroplastic insulated Silicon Rubber sheathed copper wire woven shield thermocouple extension wire
KX-HA-FGRP Fluoroplastic insulated Silicon Rubber sheathedcopper wire woven shield thermocouple soft extension wire
KX-HA-FV Fluoroplastic insulated PVC sheathed thermocouple extension wire
KX-HA-FVR Fluoroplastic insulated PVC sheathed thermocouple soft extension wire
KX-HA-FVP Fluoroplastic insulated PVC sheathed thermocouple copper wire woven shield extension wire
KX-HA-FVRP Fluoroplastic insulated PVC sheathed thermocouple copper wire woven shield soft extension wire
KX-GA-YJV XLPE insulated PVC sheathed thermocouple extension wire
KX-GA-YJVR XLPE insulated PVC sheathed thermocouple soft extension wire
KX-GA-YJVP XLPE insulated PVC sheathed thermocouple copper wire woven shield extension wire
KX-GA-YJVRP XLPE insulated PVC sheathed thermocouple copper wire woven shield soft extension wire
KX-GA-YDVD Low-smoke Halogen-free insulated and sheathed thermocouple extension wire
KX-GA-YDVDR Low-smoke Halogen-free insulated and sheathed thermocouple soft extension wire
KX-GA-YDVDP Low-smoke Halogen-free insulated and sheathed thermocouple copper wire woven shield extension wire
KX-GA-YDVDRP Low-smoke Halogen-free insulated and sheathed thermocouple copper wire woven shield soft extension wire

Note:Only KX series listed above.For SC,KC,EX,BC,TX,JX series,only replace KX with SC etc.

ZR is added to flame retardant type.ZR-182 used imported PFA,260℃ resistant.

The shield layer can be tinned copper wire.

4.2Intrinsically safe thermocouple extension wire(precision class,gradiation No.K)

Model Name
IA-KX-GA-YVP PE insulated and PVC sheathed copper wire woven shield intrinsically safe thermocouple extension wire
IA-KX-GA-YVRP PE insulated and PVC sheathed copper wire woven shield intrinsically safe thermocouple extension soft wire
IA-KX-GA-FFP Fluoroplastic insulated and PVC sheathed copper wire woven shield intrinsically safe thermocouple extension wire
IA-KX-GA-FFRP Fluoroplastic insulated and PVC sheathed copper wire woven shield intrinsically safe thermocouple extension soft wire
IA-KX-GA-FGP Fluoroplastic insulated and Silicon rubber sheathed copper wire woven shield intrinsically safe thermocouple extension wire
IA-KX-GA-FGRP Fluoroplastic insulated and Silicon rubber sheathed copper wire woven shield intrinsically safe thermocouple extension soft wire
Note:Only KX series listed above.For SC,KC,EX,BC,TX,JX series,only replace KX with SC etc.

ZR is added to flame retardant type.ZR-182 used imported PFA,260℃ resistant.

The shield layer can be tinned copper wire.


4.3 Extension Wire(precision class,gradiation No.K)

Model Name
KX-GA-VVP PVC insulated and sheathed woven copper wire general shield thermocouple extension wire
KX-GA-VVRP PVC insulated and sheathed woven copper wire general shield soft thermocouple extension wire
KX-HA-VPVP PVC insulated and sheathed woven copper wire seperate shield and general shield thermocouple extension wire
KX-HA-VPVRP PVC insulated and sheathed woven copper wire seperate shield and general shield soft thermocouple extension wire
KX-GA-YJVP XLPE insulated PVC sheathed woven copper wire general shield thermocouple extension wire
KX-GA-YJVRP XLPE insulated PVC sheathed woven copper wire general shield soft thermocouple extension wire
KX-GA-YJVPVP XLPE insulated PVC sheathed woven copper wire seperate shield and general shield thermocouple extension wire
KX-GA-YJPVRP XLPE insulated PVC sheathed woven copper wire seperate shield and general shield soft thermocouple extension wire
KX-HA-FFP Fluoroplastic insulated and sheathed woven copper wire general shield thermocouple extension wire
KX-HA-FFRP Fluoroplastic insulated and sheathed woven copper wire general shield soft thermocouple extension wire
KX-HA-FPFP Fluoroplastic insulated and sheathed woven copper wire seperate shield and general shield thermocouple extension wire
KX-HA-FPFRP Fluoroplastic insulated and sheathed woven copper wire seperate shield and general shield soft thermocouple extension wire
KX-HA-FVP Fluoroplastic insulated PVC sheathed woven copper wire general shield thermocouple extension wire
KX-HA-FVRP Fluoroplastic insulated PVC sheathed woven copper wire general shield soft thermocouple extension wire
KX-HA-FPVP Fluoroplastic insulated PVC sheathed woven copper wire seperate shield and general shield thermocouple extension wire
KX-HA-FPVRP Fluoroplastic insulated PVC sheathed woven copper wire seperate shield and general shield soft thermocouple extension wire
KX-HA-FGP Fluoroplastic insulated Silicon rubber sheathed woven copper wire general shield thermocouple extension wire
KX-HA-FGRP Fluoroplastic insulated Silicon rubber sheathed woven copper wire general shield soft thermocouple extension wire
KX-HA-FPGP Fluoroplastic insulated Silicon rubber sheathed woven copper wire seperate shield and general shield thermocouple extension wire
KX-HA-FPGRP Fluoroplastic insulated Silicon rubber sheathed woven copper wire seperate shield and general shield soft thermocouple extension wire

Note:Only Copper wire shield or Tinned Copper wire shield listed above.As for other type of shield,only replace sheath code for,such as,P2,P3,etc.

ZR can be added to flame retardant series.22 can be added to the code end of armored cable.ZR182 used imported PFA,260℃ resistant

4.4 Intrinsically safe extension wire(precision class,gradiation No.K)

Model Name
IA-KX-GA-FPVP Fluoroplastic insulated and PVC sheathed woven copper wire seperate shield and general shield intrinsically safe thermocouple extension wire
IA-KX-GA-FPVRP Fluoroplastic insulated and PVC sheathed woven copper wire seperate shield and general shield intrinsically safe soft thermocouple extension wire
IA-KX-HA-FPFP Fluoroplastic insulated and sheathed woven copper wire seperate shield and general shield intrinsically safe thermocouple extension wire
IA-KX-HA-FPFRP
Fluoroplastic insulated and sheathed woven copper wire seperate shield and general shield intrinsically safe soft thermocouple extension wire
IA-KX-HA-FPGP
Fluoroplastic insulated and SIlicon rubber sheathed woven copper wire seperate shield and general shield intrinsically safe thermocouple extension wire
IA-KX-HA-FPGRP
Fluoroplastic insulated and SIlicon rubber sheathed woven copper wire seperate shield and general shield intrinsically safe soft thermocouple extension wire
Note:Only Copper wire shield or Tinned Copper wire shield listed above.As for other type of shield,only replace sheath code for,such as,P2,P3,etc.

ZR can be added to flame retardant series.22 can be added to the code end of armored cable.ZR182 used imported PFA,260℃ resistant

5.Thermocouples Extension Cable show

thermocouple-extension-wire-show.jpg

CONTACT WITH US NOW

Our mail: manager@hiseamarine.com

Society certificates

Hi-Sea Group-Obtained-certification