Shearer shield monitor reinforced cable

Shearer shield monitor reinforced cable

Shearer shield monitor reinforced cable

1. rated voltage Uo / U 0.66/1.14KV,1.9/3.3kv

2.used to power rated vlotage 0.66/1.14kv,1.9/3.3 shearer and similar equiipments

3.Reiforced layer adopts galvanized steel wire and tinned copper bundle or twisted structure

4.long-term allowable working temperature of cable conductor to 65 ℃.

5.the wrapped reinforced cable minimum bend radius of the cable is 6 times the diameter of the wire while woven reinforced cable is 6 times as its diameter.

6.Ground core should connect with earth well.

7.This cable has two type of reinforcement,woven reinforced and wrapped reinforced.

If you feel this is not what you are looking for,please kindly check more shearer cable here,also you can check more cable here,or you can use the search form on the upper right corner.

Shearer shield monitor reinforced cable Model

Model Product Name Application
MCPJB-0.66/1.14 Shearer Shield Monitor Woven Reinforced Rubber Sheath Flexible Cable power connection for Shearer and Similar equipment rated voltage no more than 0.66/1.14kv,Draggable
MCPJB-1.9/3.3 Shearer Shield Monitor Woven Reinforced Rubber Sheath Flexible Cable
power connection for Shearer and Similar equipment rated voltage no more than 1.9/3.3kv,Draggable
MCPJR-0.66/1.14 Shearer Shield Monitor Wrapped Reinforced Rubber Sheath Flexible Cable
power connection for Shearer and Similar equipment rated voltage no more than 0.66/1.14kv,Protection Board Needed
MCPJR-1.9/3.3 Shearer Shield Monitor Wrapped Reinforced Rubber Sheath Flexible Cable
power connection for Shearer and Similar equipment rated voltage no more than 1.9/3.3kv,Protection BoardNeeded

0.66/1.14kv Shearer shielded monitor reinforced rubber sheathed cable specifications:

Core Number*Section(mm2) Insulator Layer Thickness (mm) Sheath layer thickness(mm) Outer Diameter Minimum insulation resistance of 20 degrees Celsius
(MΩ.Km)
Power Core Ground Core Control Core Monitoring Core Power Core Inner Sheath Outer Sheath MCPJR-0.66/1.14 MCPJB-0.66/1.14
3*35 1*16 3*1.5 3*1.5 1.8 1.8 3.0 40.5~46.0 43.5~49.0 250
3*50 1*25 3*1.5 3*1.5 1.8 2.0 3.5 46.5~52.5 49.5~55.7 250
3*70 1*35 3*1.5 3*1.5 1.8 2.0 3.5 51.0~57.5 54.0~61.0 200
3*95 1*50 3*1.5 3*1.5 2.0 2.4 4.0 57.5~64.5 60.5~68.0 200
Note:

1.Control Conduct core nominal thickness is 0.7mm,no assessment requirements for inner sheath thickness

2.Monitoring and Control core should reinforced with steel wire or equivalent material

3.Monitoring core adopt twined tinned copper wire that maximum diameter no more than 0.21mm.

4.Control Core insulation resistance of 20 degrees Celsius should be no less than 100MΩ.Km

1.9/3.3kv Shearer shielded monitor reinforced rubber sheathed cable specifications:

Core Number*Section(mm2) Insulator Layer Thickness (mm) Sheath layer thickness(mm) Outer Diameter Minimum insulation resistance of 20 degrees Celsius
(MΩ.Km)
Power Core Ground Core Control Core Monitoring Core Power Core Inner Sheath Outer Sheath MCPJR-1.9/3.3 MCPJB-1.9/3.3
3*35 1*16 3*1.5 3*1.5 2.8 1.8 3.0 46.5~52.0 49.5~55.0 400
3*50 1*25 3*1.5 3*1.5 2.8 2.0 3.5 51.5~57.5 54.5~61.0 350
3*70 1*35 3*1.5 3*1.5 2.8 2.0 3.5 56.0~62.5 59.0~66.0 250
3*95 1*50 3*1.5 3*1.5 2.8 2.4 4.0 62.5~68.5 64.5~72.0 200
Note:

1.Control Conduct core nominal thickness is 0.7mm,no assessment requirements for inner sheath thickness

2.Monitoring and Control core should reinforced with steel wire or equivalent material

3.Monitoring core adopt twined tinned copper wire that maximum diameter no more than 0.21mm.

4.Control Core insulation resistance of 20 degrees Celsius should be no less than 100MΩ.Km

Shearer shielded monitor reinforced rubber sheathed cable structure: