JIS C3410 Control Cable
JIS C3410 Control Cable
JIS C3410 Control Cable application
This product is suitable for all kinds of ships and offshore oil platforms and other control structures and electrical transmission .
JIS C3410 Control Cable Service condition
Voltage rating: 250VMaximum conductor temperature: 85°C
JIS C3410 Control Cable Applied Standard
-JISC 3410-1999-IEC 60092-350
-IEC 60332-1
-IEC 60332-3 Cat.AF(for FA-type)
JIS C3410 Control Cable Construction
Conductor |
M |
Tinned annealed stranded copper, class 2 according to IEC 60228 |
Insulation |
P |
85°C EPR as per JIS C 3401 |
Cabling |
|
Insulated conductors shall be cabled. |
Bedding |
Y |
PVC as per JIS C 3401 |
Armor |
C |
Galvanized steel wire braid |
Sheath |
Y |
PVC as per JIS C 3401 |
Core identification |
|
Black No. on white insulation /Black No. on white insulation, G/Y |
Outer sheath color |
|
Black |
JIS C3410 Control Cable Parameter
250V (FA-) MPY
No. of cores |
Conductor |
Thick. of insulation |
Thick. of bedding |
(FA-) MPY | ||||
Size | Construction | O.D |
Nom. overall dia |
Tolerance |
Cable Weight |
|||
mm² | No./mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
1.1 |
8.7 |
0.4 |
85 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
1.1 |
9.9 |
0.4 |
125 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
1.2 |
11.9 |
0.5 |
190 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
1.3 |
15.5 |
0.7 |
315 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
1.4 |
18.3 |
0.8 |
465 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
1.6 |
22.1 |
0.9 |
665 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
1.7 |
24.8 |
1 |
870 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
1.8 |
28 |
1.2 |
1160 |
77 |
1 |
7/0.43 |
1.29 |
0.7 |
2.1 |
35.9 |
1.5 |
1790 |
250V (FA-) MPYC
No. of cores |
Conductor |
Thick. of insulation |
Thick. of bedding |
Dia. of steel wire |
(FA-) MPYC | ||||
Size | Construction | O.D |
Nom. overall dia |
Tolerance |
Cable Weight |
||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
1.1 |
0.3 |
10 |
0.4 |
155 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
1.1 |
0.3 |
11.2 |
0.4 |
205 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
1.2 |
0.3 |
13.2 |
0.5 |
290 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
1.3 |
0.3 |
16.8 |
0.7 |
445 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
1.4 |
0.3 |
19.6 |
0.8 |
615 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
1.6 |
0.3 |
23.4 |
0.9 |
840 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
1.7 |
0.3 |
26.1 |
1 |
1070 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
1.8 |
0.3 |
29.3 |
1.2 |
1290 |
77 |
1 |
7/0.43 |
1.29 |
0.7 |
2.1 |
0.4 |
37.7 |
1.5 |
2180 |
250V (FA-) MPYCY
No. of cores |
Conductor |
Thick. of insulation |
Thick. of bedding |
Dia. of steel wire |
Thick. of covering |
(FA-) MPYCY | ||||
Size | Construction | O.D |
Nom. overall dia |
Tolerance |
Cable Weight |
|||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
1.1 |
0.3 |
0.9 |
12 |
0.5 |
205 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
1.1 |
0.3 |
0.9 |
13.2 |
0.5 |
260 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
1.2 |
0.3 |
0.9 |
15.2 |
0.6 |
350 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
1.3 |
0.3 |
1 |
19 |
0.8 |
530 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
1.4 |
0.3 |
1.1 |
22 |
0.9 |
720 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
1.6 |
0.3 |
1.2 |
26 |
1 |
980 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
1.7 |
0.3 |
1.3 |
28.9 |
1.2 |
1240 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
1.8 |
0.3 |
1.3 |
32.1 |
1.3 |
1470 |
77 |
1 |
7/0.43 |
1.29 |
0.7 |
2.1 |
0.4 |
1.5 |
41.1 |
1.6 |
2470 |
JIS C3410 Control Cable Show