Foam PE insulation metal sheathed symmetrical communication cable
Foam PE insulation metal sheathed symmetrical communication cable application
PCM digital quads for a group (2.048Mb / s) digital communication systems, low-frequency Quads for audio communication, 0.6 line pairs for signal, alarm, telemetry, remote exploration and audio communication.
Foam PE insulation metal sheathed symmetrical communication cable model and spec
Model
|
Name
|
HESYFL22
|
Copper Core foam PE insulation aluminum sheathed steel tape armored PE outer sheathed Digital long distance symmetrical communication cable
|
HESYFL23 | Copper Core foam PE insulation aluminum sheathed steel tape armored PVC outer sheathed Digital long distance symmetrical communication cable |
(1) 14 sets of digital transmission distance symmetrical communication cables
0.9 * 4 * 4 (number) +10 * 4 * 0.9 (low) 0.6 +5 * 2 *
(2) 17 sets of numbers symmetrical communication cable transmission distance
0.9 * 4 * 4 (number) +13 * 4 * 0.9 (low) + 4 * 4 * 0.6 (low) 2 * 0.6 +1 *
Foam PE insulation metal sheathed symmetrical communication cable features
(1) Digital Quads for PCM primary group (2048Mbit / s) digital communications system
(2) low-frequency Quads for audio communication
(3) 0.6,0.7 pair for signal, alarm, telemetry and audio communication
(4) shielding factor of ≤ 0.1
(5) applies to strong electromagnetic interference occasions
Foam PE insulation metal sheathed symmetrical communication cable electrical performance
Number
|
Item
|
Data
|
Conversion formula
|
1
1-1
1-2
|
Digital Quads crosstalk attenuation 103KHz dB/km
Near-end crosstalk attenuation between the two groups 100% 80%
The group FEXT defense degree 100% 80%
|
≥70 ≥75
≥50 ≥55
|
-10lg(L/500)
|
2
|
Digital Quads capacitive coupling coefficient pF/500m K2 K3(0.8~1.0KHz) |
≤600
|
L/500
|
3
|
Low-frequency capacitive coupling coefficient Quads pF/500m (0.8~1.0KHz)
K1 Average Max
K9~K12 Average Max
|
≤82 330
<119 236
|
√L/500 L/500
√L/500 L/500
|
![]()
4
|
LF Quads ground capacitance unbalance pF/500m (0.8~1.0KHz)
e1 、 e2 Ave Max
10% of the maximum allowed number plate
|
≤233 800
1294
|
√L/500 L/500
L/500
|
5
|
Insulation resistance core - ground MΩ.km
Digital and low frequency Quads
0.6 0.7 0.6 solid line on the low-frequency Quads
|
≥10000
≥5000
|
1000/L
|
6
|
Insulation electric strength(50Hz) V
Digital Quads and Low-frequency Quads
Core-Core 2min
Core-Metal sheath 2min
0.6、 0.7pair - 0.6solid low frequency quads 2min
Core-Metal sheath 2s
|
1000
1800
1000
2000
|
-
|
7
|
Shielding factor
Longitudinal sheath induced electromotive force 30~150V/km (50Hz)
|
≤0.1
|
-
|
Note:100%, 80% for the cable measured group number
Foam PE insulation metal sheathed symmetrical communication cable typical construction
1.Conductor
2.Insulation
3.Tape
4.Aluminum sheath
5.Inner covering
6.Outer sheath
Society certificates

CONTACT WITH US NOW