Foam PE insulation metal sheathed symmetrical communication cable
Foam PE insulation metal sheathed symmetrical communication cable application
PCM digital quads for a group (2.048Mb / s) digital communication systems, low-frequency Quads for audio communication, 0.6 line pairs for signal, alarm, telemetry, remote exploration and audio communication.
Foam PE insulation metal sheathed symmetrical communication cable model and spec
Model
|
Name
|
HESYFL22
|
Copper Core foam PE insulation aluminum sheathed steel tape armored PE outer sheathed Digital long distance symmetrical communication cable
|
HESYFL23 | Copper Core foam PE insulation aluminum sheathed steel tape armored PVC outer sheathed Digital long distance symmetrical communication cable |
(1) 14 sets of digital transmission distance symmetrical communication cables
0.9 * 4 * 4 (number) +10 * 4 * 0.9 (low) 0.6 +5 * 2 *
(2) 17 sets of numbers symmetrical communication cable transmission distance
0.9 * 4 * 4 (number) +13 * 4 * 0.9 (low) + 4 * 4 * 0.6 (low) 2 * 0.6 +1 *
Foam PE insulation metal sheathed symmetrical communication cable features
(1) Digital Quads for PCM primary group (2048Mbit / s) digital communications system
(2) low-frequency Quads for audio communication
(3) 0.6,0.7 pair for signal, alarm, telemetry and audio communication
(4) shielding factor of ≤ 0.1
(5) applies to strong electromagnetic interference occasions
Foam PE insulation metal sheathed symmetrical communication cable electrical performance
Number
|
Item
|
Data
|
Conversion formula
|
1
1-1
1-2
|
Digital Quads crosstalk attenuation 103KHz dB/km
Near-end crosstalk attenuation between the two groups 100% 80%
The group FEXT defense degree 100% 80%
|
≥70 ≥75
≥50 ≥55
|
-10lg(L/500)
|
2
|
Digital Quads capacitive coupling coefficient pF/500m K2 K3(0.8~1.0KHz) |
≤600
|
L/500
|
3
|
Low-frequency capacitive coupling coefficient Quads pF/500m (0.8~1.0KHz)
K1 Average Max
K9~K12 Average Max
|
≤82 330
<119 236
|
√L/500 L/500
√L/500 L/500
|
4
|
LF Quads ground capacitance unbalance pF/500m (0.8~1.0KHz)
e1 、 e2 Ave Max
10% of the maximum allowed number plate
|
≤233 800
1294
|
√L/500 L/500
L/500
|
5
|
Insulation resistance core - ground MΩ.km
Digital and low frequency Quads
0.6 0.7 0.6 solid line on the low-frequency Quads
|
≥10000
≥5000
|
1000/L
|
6
|
Insulation electric strength(50Hz) V
Digital Quads and Low-frequency Quads
Core-Core 2min
Core-Metal sheath 2min
0.6、 0.7pair - 0.6solid low frequency quads 2min
Core-Metal sheath 2s
|
1000
1800
1000
2000
|
-
|
7
|
Shielding factor
Longitudinal sheath induced electromotive force 30~150V/km (50Hz)
|
≤0.1
|
-
|
Note:100%, 80% for the cable measured group number
Foam PE insulation metal sheathed symmetrical communication cable typical construction
1.Conductor
2.Insulation
3.Tape
4.Aluminum sheath
5.Inner covering
6.Outer sheath
CONTACT WITH US NOW