- Home
- > Cable
- > Power Cable
Five core PVC insulated and sheathed power cable
Five core PVC insulated and sheathed power cable application
This product is intended for power transmission of rated voltage 3.6/6KV and below.Five core power cable is needed to meet the development and security of the power distribution system, the neutral voltage distribution system works separately with the zero line, make the system run more stable, to protect the safety of operating personnel.Our five core power cable is patented product.
Five core PVC insulated and sheathed power cable service conditions and features
1, the insulated core identification using three: insulation color extrusion; monochrome, with 0,1,2,3,4 coded identification; color, color bar crowded.2, five-core cables for power transmission and distribution of three-phase five-wire system, due to the neutral wire core separated from ground makes the system more stable, more secure operating personnel. And five-core power cable with a unique tile-shaped design, the cable has a stable structure, light weight, small diameter characteristics.
3, the maximum rated operating temperature of cable conductor is 70 ℃;
4, short circuit (the longest duration of no more than 5S), the maximum operating temperature of cable conductor is 160 ℃;
5, The ambient temperature should not be less than 0 ℃;
6,Bending diameter cabling as: single-core cable is not less than 40 times the cable diameter;Multi-core cable is not less than 30 times the cable diameter.
Five core PVC insulated and sheathed power cable Model
Product model
|
Name
|
|
Copper core
|
Aluminum Core
|
|
VV | VLV | Copper(Aluminum) Conductor PVC insulated and sheathed power cable |
VV22 | VLV22 | Copper(Aluminum) Conductor PVC insulated and sheathed steel tape armored power cable |
VV32 | VLV32 | Copper(Aluminum) Conductor PVC insulated and sheathed thin steel tape armored power cable |
VV42 | VLV42 | Copper(Aluminum) Conductor PVC insulated and sheathed thick steel wire armored power cable |
Five core PVC insulated and sheathed power cable specification
Product Model |
Cores | Nominal Area(mm2) | |
Copper Core | Aluminum Core | ||
VV | VLV |
1 2 3 3+1 4 4+1 3+2 5 |
1.5~800 1.5~185 1.5~300 4~300 4~300 4~185 4~185 4~185 |
VV22 |
VLV22 |
||
VV32 |
VLV32 |
||
VV42 |
VLV42 |
Five core PVC insulated and sheathed power cable technical performance
DC resistance of the conductor complies with the requirements of GB/T3956-1997.
Finished cable insulation meets GB12706.1 requirements. Finished cable should withstand A.C voltage listed table below for 5 minutes no breakdown.
U0/U(kV)
|
0.6/1
|
1/1
|
1.8/3
|
3/3
|
3.6/6
|
Us(kV)
|
3.5
|
4.5
|
6.5
|
9.5
|
11
|
Five core PVC insulated and sheathed power cable construction
1-Conductor
2-Insulation
3-Tape
4-Sheath
CONTACT WITH US NOW