- Home
- > Cable
- > Power Cable
Rubber insulated power cable
Rubber insulated power cable
Rubber insulated power cable introduction
Rubber insulated power cable insulation layer is SBR rubber or butyl rubber. 6-35kV rubber insulated cables, wires surface of semi-conductive shielding layer, an insulating layer surface with semi-conductive material and a metal shield combination. Multi-core cables insulated cores twisted, the use of corrosion resistant fiber fill and pack with blanket fiberglass tape or adhesive tape. Rubber cable jacket is generally poly vinyl grip sheath or neoprene rubber sheath.
Rubber insulated cable insulation softness best and the conductor strands root number slightly more than other types of cable, so cable laying Easy installation, suitable for larger gap and bend radius smaller occasions. It can be used for fixed laying power lines can also be used to move periodically laid lines. But when the rubber insulation will quickly damage the oil encountered in high voltage stress cracks susceptible to corona effect, so this cable is generally used At 10kV and below voltage level.
Rubber insulated power cable features
1. Generally buried in the soil or laying indoors, trenches, tunnels, insulation distance between lines is small, no tower, small footprint, the surface area of almost no space.2. Influenced by climatic conditions and the surrounding environmental impact, transport, stable performance, high reliability.
3. With the high pressure, high-capacity development more favorable conditions, such as temperature, superconducting power cables.
4. Distributed capacitance larger.
5. Less maintenance.
6. Possibility of a small electric shock.
Rubber insulated power cable application
As with rubber insulation and sheath of wires, cables.
Usually the metal conductor, the shield, rubber insulation and sheath components.
By purpose are power cables, control and signal cables, marine cables, aviation cables, mining cables, mounting electrical wiring.
Insulation and sheath made of natural rubber, styrene-butadiene rubber, ethylene-propylene rubber production, in addition to meeting insulating properties and mechanical properties, the requirements of anti-aging, wear, some products require oil resistance, flame retardant.
Wires, cables for general use extrusion, continuous hot air vulcanization. Products are used in all walks of life.
Rubber insulated cables with insulating rubber as the insulating materialmay be folded repeatedly bent inward but with poor capability against destructive forces, generally used in rated voltage less than 10KV, using the hanging laying rarely for underground laying. For traffic, cranes and other mobile machinery supply cable more.
Rubber insulated power cable standards
GB 5013-1997 rated voltage 450/750V rubber insulated cables
GB7594.8-1987 wire and cable Rubber insulation and sheath
GB / T 12706-2002 (equivalent with IEC502), flame retardant cable, fire-resistant cable is also in line IE332-3, IEC331, may also produce technical requirements required by the user.
Rubber insulated power cable construction
Rubber insulated power cable technical parameter
65℃ Ampere capacity
Main Core Cross-section area(mm²) |
YZ、YZW、YHZ(A) |
YQ、YQW、YHQ(A) |
||||||||||||||
2 Core |
3Cores、4Cores |
2 Cores |
3 Cores |
|||||||||||||
20℃ |
30℃ |
35℃ |
40℃ |
25℃ |
30℃ |
35℃ |
40℃ |
25℃ |
25℃ |
|||||||
0.75 |
12 |
11 |
10 |
9 |
9 |
8 |
7 |
7 |
11 |
9 |
||||||
0.75 |
14 |
13 |
12 |
11 |
11 |
10 |
9 |
8 |
14 |
12 |
||||||
1.0 |
17 |
15 |
14 |
13 |
13 |
12 |
11 |
10 |
- |
- |
||||||
1.5 |
21 |
19 |
18 |
16 |
18 |
16 |
15 |
14 |
- |
- |
||||||
2.0 |
26 |
24 |
22 |
20 |
22 |
20 |
19 |
17 |
- |
- |
||||||
2.5 |
30 |
28 |
25 |
23 |
25 |
23 |
21 |
19 |
- |
- |
||||||
4 |
41 |
38 |
35 |
32 |
36 |
32 |
30 |
27 |
- |
- |
||||||
6 |
53 |
49 |
45 |
41 |
45 |
42 |
38 |
35 |
- |
- |
Continuous ampere capacity
Model |
YQ YQW YZ YZW YC YCW |
||||||||||||||
Rated Voltage(KV) |
0.45/0.75 |
||||||||||||||
Cores |
1 |
2 |
3 |
4 |
5 |
||||||||||
Conductor Operating temperature(°C) |
65 |
||||||||||||||
Ambient temperature(°C) |
30 |
35 |
40 |
30 |
35 |
40 |
30 |
35 |
40 |
30 |
35 |
40 |
30 |
35 |
40 |
Nominal Cross-section area(mm2) |
Copper conductor laying on ground |
||||||||||||||
1.5 |
24 |
22 |
20 |
19 |
17 |
16 |
17 |
15 |
14 |
15 |
14 |
13 |
14 |
13 |
12 |
2.5 |
32 |
29 |
27 |
27 |
25 |
23 |
22 |
21 |
19 |
21 |
20 |
18 |
19 |
17 |
16 |
4 |
42 |
39 |
36 |
35 |
33 |
30 |
31 |
28 |
26 |
28 |
26 |
24 |
26 |
24 |
22 |
6 |
55 |
51 |
47 |
46 |
43 |
39 |
39 |
36 |
33 |
35 |
33 |
30 |
33 |
31 |
28 |
10 |
78 |
72 |
66 |
65 |
60 |
55 |
55 |
51 |
47 |
51 |
47 |
43 |
47 |
44 |
40 |
16 |
103 |
95 |
87 |
86 |
80 |
73 |
73 |
68 |
62 |
66 |
61 |
56 |
63 |
58 |
53 |
25 |
136 |
125 |
115 |
113 |
105 |
96 |
98 |
90 |
83 |
84 |
77 |
71 |
83 |
76 |
70 |
35 |
165 |
153 |
140 |
136 |
125 |
115 |
118 |
109 |
100 |
116 |
107 |
98 |
- |
- |
- |
50 |
212 |
196 |
180 |
177 |
164 |
150 |
153 |
142 |
130 |
136 |
125 |
115 |
- |
- |
- |
70 |
260 |
240 |
220 |
218 |
202 |
185 |
189 |
174 |
160 |
165 |
153 |
140 |
- |
- |
- |
95 |
313 |
289 |
265 |
260 |
240 |
220 |
224 |
207 |
190 |
201 |
185 |
170 |
- |
- |
- |
120 |
366 |
338 |
310 |
- |
- |
- |
266 |
245 |
225 |
230 |
213 |
195 |
- |
- |
- |
150 |
425 |
392 |
360 |
- |
- |
- |
301 |
278 |
255 |
266 |
245 |
225 |
- |
- |
- |
185 |
478 |
441 |
405 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
240 |
573 |
529 |
485 |
- |
- |
- |
- |
- |
- |
- |
-- |
- |
- |
- |
- |
Rubber insulated power cable show
Rubber insulated power cable sample
Rubber insulated power cable sample 2
CONTACT WITH US NOW