AWS E8015-C2 Low Temperature Steel Electrode
W907Ni
GB:E5515-C2
AWS:E8015-C2
Current:Used for welding 3.5Ni low temperature low-alloy steel structures under -90��.
AWS:E8015-C2
Current:Used for welding 3.5Ni low temperature low-alloy steel structures under -90��.
W907Ni |
According with GB E5515-C2 Corresponding with AWS E8015-C2 |
||||||||||||||
|
|||||||||||||||
|
|||||||||||||||
Chemical Composition of Deposited Metal (%)
|
|||||||||||||||
Mechanical Properties of Deposited Metal
|
|||||||||||||||
Diffusible Hydrogen Content in Deposited Metal: ≤6.0ml/100g(Glycerine Hydrogen Test) |
|||||||||||||||
X-ray Radiographic Inspection: ⅠDegree |
|||||||||||||||
Reference Current (DC+)
|
|||||||||||||||
Instructions: 1.The electrodes must be baked under about 350℃ for an hour before welding, and used as soon as baking is completed. 2.The weldments must be preheated under about 150℃ before welding to avoid cracks. 3.If the stress in the weldments needs eliminating, they should be tempered under 600-650℃ after welding. |
|
CONTACT WITH US NOW