AWS E12015-G Low-alloy Steel Electrode
J857Cr
GB:E8515-G
AWS:E12015-G
Current:Used for welding pressure vessels made of low-alloy high strength steel with tensile strength of about 830MPa and some other structures, such as 14CrMnMoVB, 30CrMo, 35CrMo, etc.
AWS:E12015-G
Current:Used for welding pressure vessels made of low-alloy high strength steel with tensile strength of about 830MPa and some other structures, such as 14CrMnMoVB, 30CrMo, 35CrMo, etc.
According with GB E8515-G Corresponding with AWS E12015-G |
||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||
Chemical Composition of Deposited Metal (%)
|
||||||||||||||||||||||||||||
Mechanical Properties of Deposited Metal
|
||||||||||||||||||||||||||||
Diffusible Hydrogen Content in Deposited Metal: ≤5.0ml/100g(Chromatography or Mercury Method) |
||||||||||||||||||||||||||||
X-ray Radiographic Inspection: ⅠDegree |
||||||||||||||||||||||||||||
Reference Current (DC+)
|
||||||||||||||||||||||||||||
Instructions: 1.The electrodes must be baked under 350-400℃ for an hour before welding, put into a 100-150℃insulation can and taken as soon as they are needed. 2.The stains on the weldments like rust must be cleared away, and the weldments must be preheated to about 200℃. 3.Weldments can be tempered under 600-650℃ after welding so as to eliminate internal stress. |
|
CONTACT WITH US NOW