ZRG Series Steam Heating Hot Water Tank
1.Application:
This series of hot water tank is suitable for freshwater system which is heated by steam.
2. Principle description:
This series hot water tank can be combined to use with fresh water pressure tank on board, that is to use fresh water in fresh water pressure tank to replenish this tank, and then heated by steam heating elements for usage of entire vessel.
Temperature adjusting valve: open and close it according to the set temperature control range.
Pressure gauge: to show the pressure in tank.
Thermometer: to show the water temperature in tank.
Safety valve: If the pressure in tank is more than 0.63MPa, the safety valve will open to release the pressure in tank.
Note: Never wind the raw material belts into the inlet of safety valve when installing the safety valve.
3.Structure:
4. Technical Details:
Model |
ZRG- |
||||
0.12 |
0.2 |
0.3 |
0.5 |
1.0 |
|
Capacity (m3) |
0.12 |
0.2 |
0.3 |
0.5 |
1.0 |
Working Pressure (Mpa) |
0.6 |
||||
Design Pressure (Mpa) |
0.7 |
||||
Steam Pressure (Mpa) |
0.3 |
||||
Water Inlet Temp. (℃) |
15 |
||||
Water Outlet Temp. (℃) |
65 |
||||
Steam Consumption (kg/h) |
27.5 |
45 |
75 |
120 |
325 |
Heated-water Capacity (kg/h) |
275 |
450 |
750 |
1200 |
3250 |
Steam Hot-water area (m2) |
0.24 |
0.38 |
0.6 |
1.0 |
2.6 |
Weight (kg) |
155 |
205 |
222 |
286 |
343 |
DN |
400 |
500 |
600 |
700 |
900 |
A |
608 |
708 |
808 |
908 |
1108 |
B |
784 |
844 |
944 |
924 |
1164 |
H |
1241 |
1335 |
1417 |
1773 |
2090 |
d1 |
DN25 |
DN32 |
DN40 |
||
d2 |
3/4" |
1" |
|||
d3 |
DN20 |
DN25 |
|||
C |
/ |
/ |
/ |
Φ490 |
Φ630 |
L |
320 |
330 |
370 |
/ |
/ |
h1 |
271 |
266 |
291 |
490 |
533 |
h2 |
540 |
615 |
630 |
/ |
/ |
H |
1241 |
1335 |
1417 |
1773 |
2090 |
5. CCS Certificate: