- Home
- > Cable
- > General Cable
VDE H05VV-F/H05VVH2-F Power wire
VDE H05VV-F/H05VVH2-F Power wire Application
These cables are suitable for the humid environment, medium-sized mechanical equipment, such as refrigerators, washing machine, dryer and other appliances. As long as the equipment complies with the applicable specifications, these cables to ensure that the case is not in direct contact with the hot parts of the instrument, or any other heat source, also suitable for cooking and heating equipment. Some other applications of this cable include: fixed installation in furniture, partition walls, decoration, and building facilities reserved. They are not suitable for outdoor use, workers
Industry (except apparel manufacturing) or agricultural applications. Single-phase or three-phase system maximum working voltage of Uo / U 318/550 V. In the direct system, the maximum operating voltage is Uo / U 413/825 V.
VDE H05VV-F/H05VVH2-F Power wire Standard and certification
VDE H05VV-F/H05VVH2-F Power wire Technical characteristics
- Operating voltage: 300/500 V- Test voltage: 2000 V
- Dynamic bending radius: 7.5 xΦ
- Static bending radius: 4 xΦ
- The application when the operating temperature: -5 ℃ to +70 ℃
- Static can withstand temperature: -40 ℃ to +70 ℃
- Short circuit temperature: +160 ℃
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km
VDE H05VV-F/H05VVH2-F Power wire Cable structure
- Soft bare copper conductor- Follow the DIN VDE 0295 cl 5, BS 6360 cl 5, IEC 60228 cl 5 and HD 383 standards..
- PVC insulation T12 class, follow the first part of VDE-0281
- Color coded to VDE-0293-308
- Yellow-green ground wire (three conductors and above)
- PVC outer sheath TM2
VDE H05VV-F/H05VVH2-F Power wire Specification
Model
|
Core x Nominal area
|
Nominal Insulation Thickness
|
Nominal Sheath Thickness
|
Nominal O.D
|
Nominal Copper Weight
|
Nominal Cable weight
|
|
# x mm2
|
mm
|
mm
|
mm
|
kg/km
|
kg/km
|
H05VV-F
|
||||||
18(24/32)
|
2 x 0.75
|
0.6
|
0.8
|
6.4
|
14.4
|
57
|
18(24/32)
|
3 x 0.75
|
0.6
|
0.8
|
6.8
|
21.6
|
68
|
18(24/32)
|
4 x 0.75
|
0.6
|
0.8
|
7.4
|
29
|
84
|
18(24/32)
|
5 x 0.75
|
0.6
|
0.9
|
8.5
|
36
|
106
|
17(32/32)
|
2 x 1.00
|
0.6
|
0.8
|
6.8
|
19
|
65
|
17(32/32)
|
3 x 1.00
|
0.6
|
0.8
|
7.2
|
29
|
79
|
17(32/32)
|
4 x 1.00
|
0.6
|
0.9
|
8.0
|
38
|
101
|
17(32/32)
|
5 x 1.00
|
0.6
|
0.9
|
8.8
|
48
|
123
|
16(30/30)
|
2 x 1.50
|
0.7
|
0.8
|
7.6
|
29
|
87
|
16(30/30)
|
3 x 1.50
|
0.7
|
0.9
|
8.2
|
43
|
111
|
16(30/30)
|
4 x 1.50
|
0.7
|
1.0
|
9.2
|
58
|
142
|
16(30/30)
|
5 x 1.50
|
0.7
|
1.1
|
10.5
|
72
|
176
|
14(30/50)
|
2 x 2.50
|
0.8
|
1.0
|
9.2
|
48
|
134
|
14(30/50)
|
3 x 2.50
|
0.8
|
1.1
|
10.1
|
72
|
169
|
14(30/50)
|
4 x 2.50
|
0.8
|
1.1
|
11.2
|
96
|
211
|
14(30/50)
|
5 x 2.50
|
0.8
|
1.2
|
12.4
|
120
|
262
|
12(56/28)
|
3 x 4.00
|
0.8
|
1.2
|
11.3
|
115
|
233
|
12(56/28)
|
4 x 4.00
|
0.8
|
1.2
|
12.5
|
154
|
292
|
12(56/28)
|
5 x 4.00
|
0.8
|
1.4
|
13.7
|
192
|
369
|
10(84/28)
|
3 x 6.00
|
0.8
|
1.1
|
13.1
|
181
|
328
|
10(84/28)
|
4 x 6.00
|
0.8
|
1.3
|
13.9
|
230
|
490
|
10(84/28)
|
5 x 6.00
|
0.8
|
1.4
|
15.9
|
289
|
548
|
H05VVH2-F
|
||||||
18(24/32)
|
2 x 0.75
|
0.6
|
0.8
|
4.2 x 6.8
|
14.4
|
48
|
17(32/32)
|
2 x 1.00
|
0.6
|
0.8
|
4.4 x 7.2
|
19.2
|
57
|
VDE H05VV-F/H05VVH2-F Power wire Show