- Home
- > Cable
- > Special Cable
Thermocouples Extension Cables
Thermocouples Extension Cables
1.Thermocouples Extension Cable Manufacturing standard
GB/T4989-94(Equal to IEC584-3)2.Thermocouples Extension Cable Characteristics and use
General-purpose PVC insulated and sheathed, extension wires or cables have good moisture proof wear and flame proof properties.For continuous extruding technology being employed, heat-resistant, fluoroplatics insulated and sheathed extension wires or cables have improved advantages, eg.enduring high temperature extreme cold, acid/alkaline oil or water and aging the products can meet the requirements of GB/T4989-94(equal to IEC584-3).
The extension wires used in the intrinsically safe, explosion-proof temperature-measuring system employ low-capacity、low-inductance materical, which is explosion-proof. They are used under the dangerous condition to form an intrinsically safe thermocouple temperature measuring system.
3.Thermocouples Extension Cable Service Condition
3.1 Max working temperature:Heat-resistant class: 200℃(F46); 260℃(PFA), 180℃ (Silicon rubber);General-purpose class: 70℃/105℃(PVC), 90℃(XLPE), 70℃(Low-smoke, halogen-free PO), 90℃/125℃(Low-smoke, halogen-free, cross-linked PO)
3.2 Min environment temperature:PVC sheath: -40℃(fixed laying), -15℃(non-fixed laying)Fluoroplastic or silicon rubber sheath: -60℃(fixed laying), -20℃(non-fixed laying)
3.3 Allowed bending radius: ≥6 times the outer diameter of the unarmored cable;≥12 times the outer diameter of the copper tape shielded or steel tape armored cable;≥10 times the outer diameter of the fluoroplastic insulated and sheathed cable.
If you feel this is not what you are looking for,please kindly check more special cable here,also you can check more cable here,or you can use the search form on the upper right corner.
4.Thermocouples Extension Cable Model
4.1Extension Wires Used in thermocouple(precision class,gradiation No.K)
Model | Name |
KX-GA-VV | PVC insulated and sheathed thermocouple extension wire |
KX-VA-VVR |
PVC insulated and sheathed thermocouple soft extension wire |
KX-GA-VVP |
PVC insulated and sheathed thermocouple copper wire woven shield extension wire |
KX-GA-VVRP |
PVC insulated and sheathed thermocouple copper wire woven shield soft extension wire |
KX-HA-FF |
Fluoroplastic insulated and sheathed thermocouple extension wire |
KX-HA-FFR |
Fluoroplastic insulated and sheathed thermocouple soft extension wire |
KX-HA-FFP |
Fluoroplastic insulated and sheathed thermocouplecopper wire woven shield extension wire |
KX-HA-FFRP |
Fluoroplastic insulated and sheathed thermocouple copper wire woven shield soft extension wire |
KX-HA-FG |
Fluoroplastic insulated Silicon Rubber sheathed thermocouple extension wire |
KX-HA-FGR |
Fluoroplastic insulated Silicon Rubber sheathed thermocouple soft extension wire |
KX-HA-FGP |
Fluoroplastic insulated Silicon Rubber sheathed copper wire woven shield thermocouple extension wire |
KX-HA-FGRP |
Fluoroplastic insulated Silicon Rubber sheathedcopper wire woven shield thermocouple soft extension wire |
KX-HA-FV |
Fluoroplastic insulated PVC sheathed thermocouple extension wire |
KX-HA-FVR |
Fluoroplastic insulated PVC sheathed thermocouple soft extension wire |
KX-HA-FVP |
Fluoroplastic insulated PVC sheathed thermocouple copper wire woven shield extension wire |
KX-HA-FVRP |
Fluoroplastic insulated PVC sheathed thermocouple copper wire woven shield soft extension wire |
KX-GA-YJV |
XLPE insulated PVC sheathed thermocouple extension wire |
KX-GA-YJVR |
XLPE insulated PVC sheathed thermocouple soft extension wire |
KX-GA-YJVP |
XLPE insulated PVC sheathed thermocouple copper wire woven shield extension wire |
KX-GA-YJVRP |
XLPE insulated PVC sheathed thermocouple copper wire woven shield soft extension wire |
KX-GA-YDVD | Low-smoke Halogen-free insulated and sheathed thermocouple extension wire |
KX-GA-YDVDR |
Low-smoke Halogen-free insulated and sheathed thermocouple soft extension wire |
KX-GA-YDVDP |
Low-smoke Halogen-free insulated and sheathed thermocouple copper wire woven shield extension wire |
KX-GA-YDVDRP |
Low-smoke Halogen-free insulated and sheathed thermocouple copper wire woven shield soft extension wire |
Note:Only KX series listed above.For SC,KC,EX,BC,TX,JX series,only replace KX with SC etc. ZR is added to flame retardant type.ZR-182 used imported PFA,260℃ resistant. The shield layer can be tinned copper wire. |
4.2Intrinsically safe thermocouple extension wire(precision class,gradiation No.K)
Model | Name |
IA-KX-GA-YVP | PE insulated and PVC sheathed copper wire woven shield intrinsically safe thermocouple extension wire |
IA-KX-GA-YVRP | PE insulated and PVC sheathed copper wire woven shield intrinsically safe thermocouple extension soft wire |
IA-KX-GA-FFP |
Fluoroplastic insulated and PVC sheathed copper wire woven shield intrinsically safe thermocouple extension wire |
IA-KX-GA-FFRP |
Fluoroplastic insulated and PVC sheathed copper wire woven shield intrinsically safe thermocouple extension soft wire |
IA-KX-GA-FGP |
Fluoroplastic insulated and Silicon rubber sheathed copper wire woven shield intrinsically safe thermocouple extension wire |
IA-KX-GA-FGRP |
Fluoroplastic insulated and Silicon rubber sheathed copper wire woven shield intrinsically safe thermocouple extension soft wire |
Note:Only KX series listed above.For SC,KC,EX,BC,TX,JX series,only replace KX with SC etc.
ZR is added to flame retardant type.ZR-182 used imported PFA,260℃ resistant. The shield layer can be tinned copper wire. |
4.3 Extension Wire(precision class,gradiation No.K)
Model | Name |
KX-GA-VVP | PVC insulated and sheathed woven copper wire general shield thermocouple extension wire |
KX-GA-VVRP |
PVC insulated and sheathed woven copper wire general shield soft thermocouple extension wire |
KX-HA-VPVP |
PVC insulated and sheathed woven copper wire seperate shield and general shield thermocouple extension wire |
KX-HA-VPVRP |
PVC insulated and sheathed woven copper wire seperate shield and general shield soft thermocouple extension wire |
KX-GA-YJVP |
XLPE insulated PVC sheathed woven copper wire general shield thermocouple extension wire |
KX-GA-YJVRP |
XLPE insulated PVC sheathed woven copper wire general shield soft thermocouple extension wire |
KX-GA-YJVPVP |
XLPE insulated PVC sheathed woven copper wire seperate shield and general shield thermocouple extension wire |
KX-GA-YJPVRP |
XLPE insulated PVC sheathed woven copper wire seperate shield and general shield soft thermocouple extension wire |
KX-HA-FFP |
Fluoroplastic insulated and sheathed woven copper wire general shield thermocouple extension wire |
KX-HA-FFRP |
Fluoroplastic insulated and sheathed woven copper wire general shield soft thermocouple extension wire |
KX-HA-FPFP |
Fluoroplastic insulated and sheathed woven copper wire seperate shield and general shield thermocouple extension wire |
KX-HA-FPFRP |
Fluoroplastic insulated and sheathed woven copper wire seperate shield and general shield soft thermocouple extension wire |
KX-HA-FVP |
Fluoroplastic insulated PVC sheathed woven copper wire general shield thermocouple extension wire |
KX-HA-FVRP |
Fluoroplastic insulated PVC sheathed woven copper wire general shield soft thermocouple extension wire |
KX-HA-FPVP |
Fluoroplastic insulated PVC sheathed woven copper wire seperate shield and general shield thermocouple extension wire |
KX-HA-FPVRP |
Fluoroplastic insulated PVC sheathed woven copper wire seperate shield and general shield soft thermocouple extension wire |
KX-HA-FGP |
Fluoroplastic insulated Silicon rubber sheathed woven copper wire general shield thermocouple extension wire |
KX-HA-FGRP |
Fluoroplastic insulated Silicon rubber sheathed woven copper wire general shield soft thermocouple extension wire |
KX-HA-FPGP |
Fluoroplastic insulated Silicon rubber sheathed woven copper wire seperate shield and general shield thermocouple extension wire |
KX-HA-FPGRP |
Fluoroplastic insulated Silicon rubber sheathed woven copper wire seperate shield and general shield soft thermocouple extension wire |
Note:Only Copper wire shield or Tinned Copper wire shield listed above.As for other type of shield,only replace sheath code for,such as,P2,P3,etc. ZR can be added to flame retardant series.22 can be added to the code end of armored cable.ZR182 used imported PFA,260℃ resistant |
4.4 Intrinsically safe extension wire(precision class,gradiation No.K)
Model | Name |
IA-KX-GA-FPVP | Fluoroplastic insulated and PVC sheathed woven copper wire seperate shield and general shield intrinsically safe thermocouple extension wire |
IA-KX-GA-FPVRP |
Fluoroplastic insulated and PVC sheathed woven copper wire seperate shield and general shield intrinsically safe soft thermocouple extension wire |
IA-KX-HA-FPFP |
Fluoroplastic insulated and sheathed woven copper wire seperate shield and general shield intrinsically safe thermocouple extension wire |
IA-KX-HA-FPFRP |
Fluoroplastic insulated and sheathed woven copper wire seperate shield and general shield intrinsically safe soft thermocouple extension wire |
IA-KX-HA-FPGP |
Fluoroplastic insulated and SIlicon rubber sheathed woven copper wire seperate shield and general shield intrinsically safe thermocouple extension wire |
IA-KX-HA-FPGRP |
Fluoroplastic insulated and SIlicon rubber sheathed woven copper wire seperate shield and general shield intrinsically safe soft thermocouple extension wire |
Note:Only Copper wire shield or Tinned Copper wire shield listed above.As for other type of shield,only replace sheath code for,such as,P2,P3,etc.
ZR can be added to flame retardant series.22 can be added to the code end of armored cable.ZR182 used imported PFA,260℃ resistant |
CONTACT WITH US NOW