NBR insulated and sheathed Flexible control cable

NBR insulated and sheathed Flexible control cable

NBR insulated and sheathed Flexible control cable Application and features

This product is suitable for mobile electrical instruments or signal transmission with AC rated voltage 450/750V and below.This cable has features like cold-resistant, anti-oil, high tensile strength, tear resistance, flexibility and other characteristics suitable for metallurgy, electric power, machinery, ports and other industries mobile and other special requirements with occasions.

NBR insulated and sheathed Flexible control cable Service condition and standards

1. AC rated voltage: U0 / U 450/750KV. Maximum operating temperature: 70 ℃ (flame retardant to 105 ℃)
2. Minimum ambient temperature: fixed laying -40 ℃, non-fixed installation -15 ℃
3. Cable installation laying temperature should not be lower than -20 ℃.
4. Flame test comply with GB12666-90 standard

NBR insulated and sheathed Flexible control cabletechnical performance

1. Finished resistance of the conductor in line with GB3956 requirements.
2.20 ℃ insulation resistance of not less than 50MΩ/KM
2. Finished cable withstand voltage test 50HZ AC3.0KV/5min without breakdown.

NBR insulated and sheathed Flexible control cable Model

(K)YVFR

NBR insulated and sheathed Flexible control cable

(K)YVFRP

NBR insulated and sheathed Copper wire braided shield Flexible control cable

Notes: 1.For flame retardant cable, plus ZR before models.
2.conductor wire core tinned copper wire can be used.
3.if any special requirements,it can be manufactured in accordance with drawings or designed and manufactured in accordance with environmental requirements.

NBR insulated and sheathed Flexible control cable Code

Item

Code

Explaination

Flame Characteristic

ZR

Flame retardant NBR Flexible cable

Series Code

K

Control Cable

Insulation Material

YVF

Butyronitrile

Shielding Material

P

Copper wire

P1

Tinned copper wire

Conductor structure

A

Single stranded

B

7 Stranded

R

Multi-Stranded

NBR insulated and sheathed Flexible control cable Specification

Core*Nominal C.S.A(mm2)

Conductor Structure

(Number*Diameter)

(B/R)

mm

Cable Outer Diameter(mm)

Reference Weight(kg/km)

YVFR

YVFRP

YVFR

YVFRP

2*0.75

24*0.20

7.0

8.2

83

123

2*1.0

32*0.20

8.0

9.1

92

137

2*1.5

48*0.20

9.2

10.5

124

174

2*2.5

51*0.25

10.5

11.8

166

220

3*0.75

24*0.20

8.5

9.8

103

143

3*1.0

32*0.20

9.0

10.2

110

152

3*1.5

48*0.20

9.5

10.7

136

177

3*2.5

51*0.25

12.5

13.8

190

243

4*0.75

24*0.20

9.0

10.2

120

160

4*1.0

32*0.20

9.3

10.9

130

173

4*1.5

48*0.20

11.0

12.5

161

205

4*2.5

51*0.25

13.5

14.9

230

270

5*0.75

24*0.20

10.0

11.5

128

168

5*1.0

32*0.20

11.0

12.5

150

220

5*1.5

48*0.20

12.0

13.5

200

270

5*2.5

51*0.25

14.0

15.2

300

390

7*0.75

24*0.20

10.5

11.5

151

221

7*1.0

32*0.20

12.5

14.2

172

241

7*1.5

48*0.20

13.0

14.6

240

298

7*2.5

51*0.25

15.5

16.5

360

380

8*0.75

24*0.20

13.5

14.5

175

234

8*1.0

32*0.20

14.0

15.2

200

233

8*1.5

48*0.20

15.0

16.6

288

291

8*2.5

51*0.25

16.0

17.2

420

580

10*0.75

24*0.20

14.1

15.4

220

320

10*1.0

32*0.20

15.0

16.0

270

394

10*1.5

48*0.20

17.1

18.1

355

480

10*2.5

51*0.25

19.0

20.1

520

650

12*0.75

24*0.20

13.0

14.5

255

365

12*1.0

32*0.20

14.2

15.4

297

397

12*1.5

48*0.20

16.0

17.2

382

520

12*2.5

51*0.25

20.0

21.5

597

690

14*0.75

24*0.20

17.0

18.0

290

390

14*1.0

32*0.20

17.6

19.0

341

470

14*1.5

48*0.20

19.0

20.0

460

580

14*2.5

51*0.25

21.0

22.0

590

790

19*0.75

24*0.20

15.8

16.8

350

480

19*1.0

32*0.20

17.0

18.0

420

550

19*1.5

48*0.20

20.0

21.0

540

660

19*2.5

51*0.25

23.0

24.2

855

1073