chemical resistance shield control cable

chemical resistance shield control cable

chemical resistance shield control cable

chemical resistance shield control cable application

This product is used in oil refineries , petrochemical plants and general chemical plants that often exposed to aromatic solvents with rated voltage 0.6/1kv and below,intended for electrical control, monitoring lines.This cable has good resistance to chemicals , oils , solvents corrosion, but also has anti-magnetic, anti-static interference , the cable can be used for direct burial and through pipe laying .

chemical resistance shield control cable Features

1, the product has good resistance to aromatic solvents, oil, chemical resistance, shielding sulfur, water tree resistance, mosquito resistance and pressure resistance, stamping performance.
2, due to shielding layer using vertical package structure, the cable shield is better than wrapping the structure of the cable.
3, the metal shield and the inner armor equipped drainage line, forming a full shield structure. Drain wire cable is not only conducive ground handling, and to ensure the continuity of the shield.
4, with fully enclosed metal sheath electricity compared to cable diameter is small, light weight, good bending performance.
5, the cable immersed in mineral oil 60 ℃ for 10 days, the sheath does not swell, dissolve, or crack. 6, the cable in the work 60 ℃ 20% caustic soda solution immersed for 10 days, the sheath fracture tensile strength and breaking elongation rate of change does not exceed ± 30%.

chemical resistance shield control cable Model

Model
Name
LH-KYJA
Copper Core XLPE insulated Plastic Coated Al tape bonded sheath chemical resistant shield control cable
LH-KYJA23

Copper Core XLPE insulated Plastic Coated Al tape bonded sheath steel tape armored XLPE outer sheath chemical resistant shield control cable

LH-KYJA53

Copper Core XLPE insulated Plastic Coated Al tape sheath single layer steel tapecorrugated longitudinally armored XLPE outer sheath chemical resistant shield control cable

chemical resistance shield control cable Model

Model
Nominal Cross-section mm2
0.75、1.0
1.5
2.5
4
6、10
Core
LH-KYJA
2~61
2~37
2~14
2~10

LH-KYJA23

6~61
4~61
4~37
4~14
4~10

chemical resistance shield control cable Show

Chemical-resistance-control-shield-cable.jpg

If you need more information,please considering send us a message.

CONTACT WITH US NOW

Our mail: manager@hiseamarine.com

Society certificates

Hi-Sea Group-Obtained-certification